Short summary
A wafer-bonded Fabry–Perot cavity enables a compact, stable, and scalable photothermal gas sensor with a minimum detection limit of 5.1 ppm for methane.
AI-generated from the title and abstract; the full text is not read.
Key points
- Developed a compact wafer-bonded Fabry–Perot (WB-FP) cavity for photothermal spectroscopy (PTS) gas sensing.
- The WB-FP design offers permanent alignment, enabling scalable and reproducible sensor fabrication.
- Achieved a minimum detection limit (MDL) of 42 ppm for methane with a 1-second integration time.
- Further improved MDL to 5.1 ppm at 100 seconds integration time.
- Demonstrated a normalized noise-equivalent absorption (NNEA) coefficient of 3.27 × 10–7 cm–1 W Hz–1/2.
AI-generated from the title and abstract; the full text is not read.
Abstract
Abstract Currently available electrochemical and direct absorption gas sensor approaches suffer from weak molecular selectivity, challenges in miniaturization, and constraints in cost-effective large-scale manufacturing. In contrast, the integration of an interferometric cavity-assisted technique with photothermal spectroscopy (PTS) provides an alternative solution promising improved sensitivity and increased dynamic range. Here, we report a compact wafer-bonded Fabry–Perot (WB-FP) cavity fabricated using a Distributed Bragg Reflector (DBR) and demonstrate its use as a photothermal transducer for gas sensing. Unlike conventional manually assembled Fabry–Perot (FP) cavities, the proposed design defines cavity permenant alignment during fabrication, providing a pathway toward scalable and reproducible photonic gas sensors. In this architecture, a near-infrared (NIR) beam is collimated and propagated through a 500 μm spaced FP cavity to probe the photothermal effects induced by interactions between the target gas molecules and the optical pump beam inside the cavity volume. To demonstrate the applicability of the developed sensor system, the metrological figures of merit were evaluated using methane (CH4) as the targeted analyte across a range of concentrations. Targeting the absorption band centered at 6047 cm–1, the system achieves a minimum detection limit (MDL) of 42 ppm with a 1 s integration time. Allan deviation analysis further indicates an improved MDL of 5.1 ppm at an optimal integration time of 100 s, corresponding to a normalized noise-equivalent absorption (NNEA) coefficient of 3.27 × 10–7 cm–1 W Hz–1/2. These results highlight the potential of the wafer-bonded FP cavity as a scalable, compact transducer for photothermal gas sensing, bridging the route toward miniaturized, stable, cost-effective, and high-sensitivity gas technologies.
The authors' abstract, as published at the source. ACS Omega, 2026 · DOI ↗
Continue with a free account
Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Spectroscopy
SpectroscopyChemistry