Waveplate compensation, the standard method to correct polarization distortions in SHG microscopy, leaves significant residual ellipticity (up to 0.24) even in optimal configurations on a commercial microscope.
AI-generated from the title and abstract; the full text is not read.
Key points
- Waveplate compensation, a standard technique for SHG microscopy, fails to fully eliminate polarization ellipticity.
- Residual ellipticity amplitudes up to 0.24 were consistently observed under optimal waveplate configurations.
- The limitation may be caused by wavelength-dependent dichroic mirror birefringence and the broad bandwidth of femtosecond laser pulses.
- Simulations qualitatively reproduced experimental observations, supporting the proposed mechanism.
AI-generated from the title and abstract; the full text is not read.
Abstract
Polarization-resolved second harmonic generation microscopy provides structural information about non-centrosymmetric biological samples such as collagen. It involves illuminating the sample with a focused laser beam having a variable linear polarization angle and recording the second harmonic signal as a function of this angle. However, accurate linear polarization control is challenging due to ellipticity introduced by reflections from mirrors and dichroic mirrors in the optical path. Waveplate-based compensation has emerged as the standard approach to address these distortions, but its effectiveness for quantitative measurements remains incompletely characterized. Here, we reproduce an established automated waveplate compensation method, based on a rotating half-waveplate combined with a compensating quarter-waveplate, on a commercial Leica TCS SP8 MP multiphoton microscope, which is the same type of instrument the method was originally developed on. Despite significant effort, we consistently observed substantial unwanted residual polarization ellipticity, with amplitudes up to 0.24, persisting under optimal waveplate configurations. Our simulation analysis suggests that this limitation may arise from wavelength-dependent dichroic mirror birefringence combined with the broad spectral bandwidth (10 nm to 20 nm full width at half maximum) of femtosecond laser pulses. While the approach investigated here can compensate a single wavelength, different spectral components within the pulse experience different phase retardations from wavelength-dependent optical elements, potentially resulting in residual ellipticity that cannot be eliminated. Our simulations qualitatively reproduced key features of the experimental observations. These findings have important implications for quantitative polarization-resolved second harmonic generation microscopy and suggest that alternative approaches, including specimen rotation or picosecond laser sources with narrower bandwidth, should be investigated for applications requiring precise polarization control. To facilitate community investigation of these effects, we provide open-source analysis code and simulation files.
The authors' abstract, as published at the source. PLoS ONE, 2026 · DOI ↗
Continue with a free account
Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
BiophysicsBiochemistry, Genetics and Molecular Biology