Journal of Materials Science Materials in Medicine· 2026Q2
Curing-state-dependent rheology governs electrospinning of silicone elastomers for hydrophobic surface coatings
- 1citations
- Q2SCImago
- 2026year
Short summary
A novel pre-curing strategy enables the electrospinning of pure silicone elastomer nonwovens with interconnected pores, overcoming previous challenges of fiber collapse and achieving tunable fiber diameters (21-136 µm).
AI-generated from the title and abstract; the full text is not read.
Key points
- A pre-curing electrospinning strategy was developed for pure silicone elastomers, avoiding polymer blends or coaxial spinnerets.
- The transition from electrospraying to electrospinning was linked to a rheological shift, including a rise in normal stress difference to over 3000 Pa.
- Controlling pre-curing time allowed for the fabrication of nonwoven structures with interconnected pores and tunable fiber diameters (21-136 µm).
- The method provides a foundation for developing anti-fibrotic hydrophobic coatings for medical devices like cochlear implants.
AI-generated from the title and abstract; the full text is not read.
Abstract
Fibrosis around cochlear implant electrode arrays increases impedance and disrupts predictable stimulus propagation. Electrospun hydrophobic silicone coatings represent a promising strategy to mitigate fibrosis. However, electrospinning silicone elastomers remains challenging because their low glass transition temperature causes deposited fibers to collapse before curing is complete. Previous approaches have focused on developing in situ curing systems, such as heated collectors. Although fiber-like structures have been generated, nonwovens with interconnected pores have not yet been achieved. A pre-curing-based electrospinning strategy was developed that enables the fabrication of pure silicone elastomer nonwovens without the need for polymer blends, sacrificial carrier polymers, or coaxial spinnerets. Sylgard 184 dilutions in acetone and tetrahydrofuran were electrospun at different pre-curing times prior to gelation and characterized rheologically to investigate the influence of curing-induced rheological evolution on electrospinnability. Initially, the dilutions exhibited near-Newtonian flow behavior. Shortly before loss of flowability, the maximum first normal stress difference increased to 3228 Pa for acetone- and 6722 Pa for tetrahydrofuran-based systems, accompanied by increased storage modulus and more pronounced shear-thinning behavior. This rheological transition coincided with the transition from electrospraying to electrospinning. By controlling the curing time, nonwoven structures with well-defined fiber geometry and interconnected pores were successfully fabricated from Sylgard/tetrahydrofuran systems. Fiber diameters ranging from 21 µm to 136 µm were achieved by adjusting the diluent and curing time. These findings demonstrate that precise control of rheological evolution during curing enables the fabrication of structurally defined electrospun silicone elastomer nonwovens, providing a foundation for anti-fibrotic coatings on cochlear implants. Graphical abstract illustrating the influence of pre-curing Sylgard 184 silicone elastomer at 40 °C on its rheological properties and subsequent electrospinning behavior. Rheological measurements, including shear viscosity and first normal stress difference, are shown alongside a schematic of the electrospinning setup with a heated collector and infrared-assisted in situ curing. Microscopic images compare the resulting fiber morphologies after 180 and 210 minutes of pre-curing.
The authors' abstract, as published at the source. Journal of Materials Science Materials in Medicine, 2026 · DOI ↗
Continue with a free account
Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Biomaterials
BiomaterialsMaterials Science