The Journal of Physical Chemistry B· 2026Q1
Hydration and H/D Exchange-Dependent Infrared Signatures of the GCN4 Leucine Zipper
- 0citations
- Q1SCImago
- 2026year
Short summary
Vacuum-dried ATR-FTIR spectroscopy reveals distinct α-helical subpopulations in the GCN4 protein by resolving an isotopically sensitive band (1648 to 1644 cm–1) and an insensitive band (1653 cm–1) after partial deuteration.
AI-generated from the title and abstract; the full text is not read.
Key points
- Vacuum drying of proteins on ATR crystals significantly improves signal-to-noise ratio for FTIR spectroscopy by minimizing solvent interference.
- ATR-FTIR in the dry state clearly resolves Amide I, Amide II, and deuterium-shifted Amide II′ bands for the GCN4 protein.
- Hydrogen-deuterium exchange (HDX) analysis of vacuum-dried GCN4 reveals a bimodal Amide I profile.
- The bimodal Amide I profile consists of an isotopically sensitive band (1648 to 1644 cm–1) and an insensitive band (1653 cm–1).
- These bands are assigned to solvent-accessible and solvent-inaccessible α-helical regions, respectively.
AI-generated from the title and abstract; the full text is not read.
Abstract
Abstract Attenuated total reflectance Fourier-transform infrared (ATR-FTIR) spectroscopy of proteins in aqueous solution is often hindered by solvent and residual water vapor absorption, which can be partially circumvented by measuring in a vacuum-dried state. Here, we investigate the structural characteristics and hydrogen–deuterium exchange (HDX) behavior of the α-helical protein GCN4 in both the hydrated and vacuum-dried states. While residual solvent severely limits the resolution of second-derivative spectra in hydrated samples, vacuum drying produces a thin protein-rich film on the ATR crystal, markedly enhancing the signal-to-noise ratio and revealing protein vibrational features. In the dry state, the Amide I, Amide II, and deuterium-shifted Amide II′ bands are clearly resolved. Importantly, second-derivative analysis of HDX-treated samples uncovers a bimodal Amide I profile comprising an isotopically sensitive band that shifts from 1648 to 1644 cm–1 and an isotopically insensitive band at 1653 cm–1, assigned to solvent-accessible and solvent-inaccessible α-helical regions, respectively. These findings demonstrate that vacuum-dried ATR-FTIR spectroscopy effectively removes solvent-induced spectral masking and enables the resolution of distinct α-helical subpopulations after partial deuteration.
The authors' abstract, as published at the source. The Journal of Physical Chemistry B, 2026 · DOI ↗
Continue with a free account
Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
BiophysicsBiochemistry, Genetics and Molecular Biology