Hydrogen· 2026Q1
Techno-Economic Analysis of a Hybrid Battery Electric Vehicle Charging and Hydrogen Vehicle Refueling Station with PV/Battery/Hydrogen Storage System
- 1citations
- Q1SCImago
- 2026year
Short summary
An optimized hybrid station design using PV, battery, and hydrogen storage minimizes net present cost, achieving a Levelized Cost of Electricity (LCOE) of $0.2578/kWh and a Levelized Cost of Hydrogen (LCOH) of $5.10/kg with an 85.5% renewable fraction.
AI-generated from the title and abstract; the full text is not read.
Key points
- Optimal hybrid station design prioritizes PV (87.9%), battery (5.4%), and hydrogen storage (3.6%) over grid supply (3.1%).
- Achieved an LCOE of $0.2578/kWh and an LCOH of $5.10/kg.
- The system operates with a high renewable fraction of 85.5%.
- Maintaining >70% renewable fraction requires daily loads <1600 kWh and <25 kg H2.
AI-generated from the title and abstract; the full text is not read.
Abstract
The world is transitioning from fossil fuel vehicles to battery electric vehicles (BEVs) and hydrogen (H2) fuel cell electric vehicles (FCEVs). However, the sources of power generation for BEV recharging and H2 production must be renewable to minimize carbon emissions. This study aims to investigate the techno-economic feasibility of a hybrid battery electric vehicle (BEV) charging and fuel cell electric vehicle (FCEV) refueling station, with a photovoltaic (PV)-battery-H2 energy storage system that is grid-connected. The system is simulated using HOMER Pro and optimized to minimize the net present cost (NPC). The performance is analyzed based on the levelized cost of electricity (LCOE), levelized cost of hydrogen (LCOH), renewable fraction (RF), and carbon reduction. The technical analysis shows that the optimal design operates at the maximum utilization of power supply from the PV (87.9%), followed by battery energy storage (5.4%), hydrogen energy storage (3.6%), with minimum grid supply (3.1%). The optimal design results in an LCOE of $0.2578/kWh and an LCOH of $5.10/kg with 85.5% RF. The sensitivity analysis on the variation of load demand suggests that the operation of the hybrid BEV charging and FCEV refueling station should be within a range of less than 25 kg of hydrogen and 1600 kWh of load demand per day to maintain an RF value above 70%, while the LCOE and LCOH can be maintained below $0.2654/kWh and $5.25/kg, respectively. These demands correspond to the assumed daily charging of 30 BEVs at 50 kWh per vehicle and the refueling of four FCEVs at 5 kg of hydrogen per vehicle. Although other components of the hydrogen energy storage system contribute to the overall cost of hydrogen gas, the LCOH is projected to fall to $4.60/kg by 2030 solely through reductions in electrolyzer costs.
The authors' abstract, as published at the source. Hydrogen, 2026 · DOI ↗
Continue with a free account
Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Energy Engineering and Power Technology
Energy Engineering and Power TechnologyEnergy