Scientific Reports· 2026Q1
Detection and classification of failed fiber reinforced polymer composite samples under mechanical loading using YOLO11 on microscopic SEM images
- 0citations
- Q1SCImago
- 2026year
Short summary
A YOLO11n model achieved a mean average precision (mAP) of 0.821 at 6.5 ms per image for detecting and classifying six types of failure features in SEM images of fiber-reinforced polymer composites.
AI-generated from the title and abstract; the full text is not read.
Key points
- YOLO11n model applied to SEM images for detecting six fractographic features in FRP composites.
- Achieved a mean average precision (mAP@0.5) of 0.821 with processing speeds of 6.5 ms per image.
- Model trained on 125 images from 37 specimens with 1318 labeled boxes.
- Proof-of-concept study suggests potential for detector-assisted laboratory fractography.
AI-generated from the title and abstract; the full text is not read.
Abstract
The fracture surfaces of fiber-reinforced polymer (FRP) composites have multiple scale failure features that are hard to interpret manually by scanning electron microscope (SEM) and are slow to conduct. The fracture surfaces of FRP composites have multiple scale failure features that are hard to interpret manually by scanning electron microscope (SEM) and slow to conduct. This proof-of-concept study compares an anchor-free single-stage detector, YOLO11n, to localize and classify six fractographic features: fiber breakage, fiber pull-out, fiber–matrix debonding, delamination, voids and matrix debris, in SEM images of carbon- and glass-fiber/epoxy specimens failed in tension, three-point bending and short-beam shear. The data consists of 125 images with 37 specimens, with 1318 labelled boxes following written labelling criteria. The weights for the model were initialized from COCO and were updated using the Adam optimizer. YOLO11n was able to obtain mAP@0.5 = 0.821 with 6.5 ms per image on a preliminary image-level split, but the number of images per subset is not consistent with 125 images and the results may be optimistic due to the fact that images from one specimen can be split into multiple subsets. Multiple seeds, a controlled comparison between it and YOLOv5n, YOLOv8n and YOLOv9t, per-class ablations and an error analysis were performed at the level of the specimen and the groups. The study shows that it is possible to apply the method of detector-assisted laboratory fractography. It does not provide any structural-health-monitoring or safety-critical capability, and is not tested on other material systems or imaging conditions.
The authors' abstract, as published at the source. Scientific Reports, 2026 · DOI ↗
Continue with a free account
Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Industrial and Manufacturing Engineering
Industrial and Manufacturing EngineeringEngineering