Method Development and Validation for Simultaneous In Situ Fe Isotope and Multi-Element Analysis by LASS MC-ICP-MS/ICP-ToF-MS

Jialu Yu, Marcus Oelze, Mathias Schannor, Jochen Vogl et al.

Short summary

A new laser ablation split-stream (LASS) method simultaneously measures iron isotope ratios and multi-element concentrations from a single sample volume, validated for both inorganic and organic matrices.

AI-generated from the title and abstract; the full text is not read.

Key points

  • Developed a LASS MC-ICP-MS/ICP-ToF-MS approach for simultaneous in situ Fe isotope and multi-element analysis.
  • Validated the method using basaltic glass reference materials (BHVO-2G, BCR-2G) and gelatin samples.
  • Achieved δ56Fe values for BHVO-2G (0.14 ± 0.27 ‰) in agreement with solution-based measurements.
  • Elemental quantification yielded recoveries predominantly within 80-120% for inorganic matrices.
  • Demonstrated accurate simultaneous isotopic and elemental analysis across inorganic and organic matrices.

AI-generated from the title and abstract; the full text is not read.

Abstract

Abstract Simultaneous acquisition of elemental and isotopic data is essential for resolving complex geochemical and biogeochemical processes but is often limited by separate analytical workflows. Here we present a laser ablation split-stream (LASS) MC-ICP-MS/ICP-ToF-MS approach for the simultaneous determination of Fe isotope ratios and multi-element concentrations from a single ablated volume. Method performance was validated using basaltic glass reference materials (BHVO-2G, BCR-2G) and in-house gelatin samples mimicking organic matrices. The obtained δ56Fe values for BHVO-2G (0.14 ± 0.27 ‰, 2s, n = 19) agree with solution-based measurements within analytical uncertainty. Elemental quantification by LASS-ICP-ToF-MS yields recoveries predominantly within 80−120%, demonstrating reliable multi-element performance under split-stream conditions. Calibration in gelatin matrices shows linear responses (R2 = 0.89−0.98) accurately reproducing validation samples for concentrations of 250 and 400 mg kg−1. The reduced linearity is attributed to variability in ablation behavior related to gelatin film heterogeneity, elemental distribution and transient signal instability during laser ablation. The δ56Fe values for the 500 mg kg−1 gelatin sample (0.12 ± 0.31 ‰, 2s, n = 19) was within the analytical uncertainty of conventional (ns)LA-MC-ICP-MS measurements (0.17 ± 0.26 ‰, 2s, n = 9). Overall, the LASS MC-ICP-MS/ICP-ToF-MS approach enables accurate simultaneous isotopic and elemental analysis across both inorganic and organic matrices, providing an effective platform for integrated isotope−element investigations in diverse fields.

The authors' abstract, as published at the source. Analytical Chemistry, 2026 · DOI ↗

TakeawaysPremium Ask the paperFree account

Continue with a free account

Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Analytical Chemistry

Analytical ChemistryChemistry