PofoliaDaily literature tracker

Virtual Reality· 2026Q1

Validation of the HTC VIVE Ultimate Trackers compared with the Vicon motion capture system at slow, moderate and fast gait speeds

Yixuan He, Matthew A D Brodie, Juno Kim, Peter Humburg et al.

Short summary

HTC VIVE Ultimate Trackers show almost perfect agreement (CCC > 0.99) for sacrum tracking and substantial agreement (CCC > 0.98) for foot tracking compared to Vicon motion capture, but accuracy decreases at speeds above 1.5 m/s.

AI-generated from the title and abstract; the full text is not read.

Key points

  • HTC VIVE Ultimate Trackers achieved almost perfect agreement (CCC > 0.99) for sacrum tracking and substantial agreement (CCC > 0.98) for foot tracking compared to Vicon motion capture.
  • Absolute tracking errors increased with gait speed, with foot trackers exhibiting larger errors than the sacrum.
  • Accuracy declined notably at 2.0 m/s, especially for foot trajectories in the anterior-posterior direction.
  • The trackers are considered cost-effective alternatives for movement analysis at gait speeds up to 1.5 m/s.

AI-generated from the title and abstract; the full text is not read.

Abstract

Abstract Tracking foot motion is critically beneficial for a wide range of applications, from immersive entertainment through to gamified rehabilitation. This study investigated the accuracy of the HTC VIVE Ultimate Tracker against the Vicon motion capture system during human walking. Ten healthy participants (aged 24–44 years) walked on a treadmill at four speeds (0.5 m/s, 1.0 m/s, 1.5 m/s, and 2.0 m/s) while tracking both feet and the pelvis. Agreement between the two systems was evaluated using a linear mixed model, Bland–Altman plots, and concordance correlation coefficients (CCC). Absolute errors ranged from millimetre- to centimetre-level. Linear mixed model (speed × tracker location × movement direction) indicated that absolute errors increased with gait speed. Foot trackers exhibited larger errors than the sacrum location, with greater errors in the medio-lateral and anterior–posterior directions compared to the vertical direction ( p < 0.001). Bland–Altman analyses revealed widening limits of agreement at different speeds (e.g., left foot, anterior–posterior direction: − 20.09 to 20.20 mm at 0.5 m/s, − 29.97 to 27.80 mm at 2.0 m/s). Ultimate Trackers demonstrated almost perfect agreement (CCC: > 0.99) for sacrum tracking and substantial agreement for foot tracking (CCC: > 0.98). These findings highlight the Ultimate Trackers’ potential as cost-effective alternatives for the analysis of human movement, demonstrating research- and clinical-grade performance for sacrum and foot tracking during normal gait speeds (≤ 1.5 m/s). However, the finding that accuracy declined at the 2.0 m/s speed, particularly for foot trajectories and in the anterior–posterior direction, indicates the need for technical refinements for higher-speed movements.

The authors' abstract, as published at the source. Virtual Reality, 2026 · DOI ↗

TakeawaysPremium Ask the paperFree account

Continue with a free account

Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Biomedical Engineering

Biomedical EngineeringEngineering