Bioengineering· 2026Q2· Review
Programmed Tooth Movement With and Without Composite Attachments in Clear Aligner Therapy: A Systematic Review of Finite Element Analysis (FEA)
- 0citations
- Q2SCImago
- 2026year
Short summary
Finite Element Analysis (FEA) models indicate composite attachments in clear aligner therapy frequently enhance initial tooth movement expression, but this effect is dependent on the type of movement and attachment design.
AI-generated from the title and abstract; the full text is not read.
Key points
- Composite attachments in FEA models often increase initial tooth displacement in clear aligner therapy.
- The effectiveness of attachments is movement-dependent: essential for extrusion, less so for intrusion and molar movements, and least for incisor torque.
- Certain attachment shapes (horizontal rectangular, vertical rectangular, semi-ellipsoidal) were frequently reported as optimal in FEA studies.
- FEA outputs reflect initial displacement and stress, not necessarily final clinical movement, and findings are limited by confounding factors like attachment shape and position.
AI-generated from the title and abstract; the full text is not read.
Abstract
Background: Composite attachments are widely used to improve tooth-movement expression in clear aligner therapy, yet the influence of attachment morphology and position remains uncertain. This systematic review synthesised finite element analysis (FEA) evidence on how attachment shape and placement affect the initial biomechanical expression of programmed tooth movement, using the no-attachment (NA) condition as the primary comparator. Methods: Following the PRISMA 2020 statement and a PROSPERO-registered protocol (CRD420261414416), five databases (PubMed, Embase, Scopus, Web of Science, and Cochrane CENTRAL) were searched. FEA studies including an NA condition and evaluating at least one target movement, rotation, molar distalization/mesialization, torque, intrusion, or extrusion; clinical, typodont, and in vitro studies, were excluded. Eighteen studies (2019–2026; seven countries) were included in a qualitative synthesis. Risk of bias was appraised with ROBFEAD, the validated Risk of Bias tool for Finite Element Analysis in Dentistry. Results: The NA condition frequently, but not uniformly, produced lower initial target-tooth displacement than the attachment conditions, but the magnitude and direction of the attachment effect suggested a movement-dependent pattern: attachments appeared essential for extrusion, less consistent for intrusion and molar movement, and least determinative for small incisor torque. Among the shapes tested, horizontal rectangular, vertical rectangular and semi-ellipsoidal designs were those most often reported as best performing, although this reflects which shapes each study chose to model. Conclusions: In FEA models, composite attachments frequently, but not uniformly, enhanced the initial biomechanical expression of programmed movements, in a movement-dependent manner. As finite element outputs reflect initial displacement and stress rather than achieved clinical movement. These findings are hypothesis-generating and are further constrained by the frequent confounding of attachment shape with position.
The authors' abstract, as published at the source. Bioengineering, 2026 · DOI ↗
Continue with a free account
Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Orthodontics
OrthodonticsDentistry