PofoliaDaily literature tracker

Nano Research· 2026Q1

OH-compensating non-enzymatic glucose sensor based on a hexagonal metal azolate framework composite for continuous sweat monitoring

Salma Ali, Ibrahim Abdalla, Zhang Zeqi, Guoyin Chen et al.

Short summary

A novel composite material, CNFs/PPy/GO/MAF, enables accurate, non-enzymatic glucose sensing in sweat across a wide pH range by compensating for acidity-induced hydroxyl loss.

AI-generated from the title and abstract; the full text is not read.

Key points

  • A composite material (CNFs/PPy/GO/MAF) was created for non-enzymatic electrochemical glucose sensing in sweat.
  • The material compensates for sweat acidity by maintaining a continuous supply of hydroxyl groups.
  • The sensor shows high sensitivity and low detection limits across pH values of 13, 12.5, and 12.
  • Real sweat sample analysis results closely matched blood glucose levels measured by a glucometer.

AI-generated from the title and abstract; the full text is not read.

Abstract

Abstract Continuous glucose monitoring is transforming analysis by using sweat, a less invasive and more accessible fluid, to provide more accurate readings during exercise. However, obtaining accurate results remains challenging due to its acidity, which can disrupt the alkaline conditions required for non-enzymatic sensing. Herein, we developed a high-surface-area carbon nanofiber (CNF) composite functionalized with polypyrrole (PPy) and combined with a graphene oxide (GO) composite for non-enzymatic electrochemical glucose sensing in sweat. The composite was fabricated via a sequential drop-casting process using a metal-azolate framework (MAF) for its high electrochemical stability, thereby enabling OH-compensation and ensuring a continuous supply of hydroxyl (OH) groups from GO, compensating for any loss of OH caused by sweat acidity. The CNFs/PPy/GO/MAF composite works efficiently across pH levels of 13, 12.5, and 12, with detection limits of 0.033, 0.043, and 0.0145 µM (S/N = 3), respectively. The composite shows high sensitivities of 663, 259.6, and 160.85 μA/(mM·cm2) within the linear ranges of 0.003–1.6, 0.003–1.4, and 0.003–0.7 mM at pH = 13, 12.5, and 12, respectively. Additionally, the composite exhibits high selectivity, stability under decreasing pH, and good repeatability and reproducibility. It yielded sweat analysis results from real samples that closely matched blood glucose levels measured by a glucometer at all tested pH values of 13, 12.5, and 12. This confirms that the composite offers accurate, reliable, real-time, and non-invasive glucose detection under typical alkaline conditions.

The authors' abstract, as published at the source. Nano Research, 2026 · DOI ↗

TakeawaysPremium Ask the paperFree account

Continue with a free account

Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Analytical Chemistry

Analytical ChemistryChemistry