Short summary

Microelectrode arrays (MEAs) offer powerful capabilities for multiplexed electroanalysis but face significant challenges in analytical reliability and translation due to issues like diffusion-field overlap, electrode cross-talk, and fabrication variability, reframing the adoption barrier as a measurement-science problem.

AI-generated from the title and abstract; the full text is not read.

Key points

  • MEAs enable rapid, multiplexed, and spatially resolved electroanalysis.
  • Key limitations include diffusion-field overlap, electrode cross-talk, and fabrication variability.
  • The primary barrier to MEA adoption is a measurement-science problem, not just fabrication.
  • Insufficient evidence exists for accuracy, long-term stability, and interlaboratory transferability.
  • Future MEA impact depends on predictive, transferable performance, not increased complexity.

AI-generated from the title and abstract; the full text is not read.

Abstract

Microelectrode arrays (MEAs) integrate microscale mass transport, parallel signal acquisition, and miniaturized instrumentation, offering powerful capabilities for multiplexed, spatially resolved, and real-time electroanalysis. Yet their technological advancement has not produced equivalent gains in analytical reliability or translation. This review critically examines how electrochemical theory, microfabrication, array architecture, multiplexing, system integration, and validation collectively govern MEA performance and technology readiness. MEAs enable rapid responses, low capacitive currents, high-throughput measurements, and multianalyte detection. However, these benefits are frequently compromised by diffusion-field overlap, electrode cross-talk, nonuniform current distribution, fabrication variability, biofouling, matrix interference, signal drift, and unstable calibration. The literature remains dominated by sensitivity and detection-limit claims, whereas accuracy, long-term stability, device-to-device reproducibility, interlaboratory transferability, and scalable manufacturing are insufficiently demonstrated. This review therefore reframes the central barrier to MEA adoption as a measurement-science problem rather than merely a fabrication challenge. Progress requires standardized validation, reproducible manufacturing, self-calibrating arrays, coupled Multiphysics models, and interpretable artificial intelligence. The future impact of MEAs will depend on predictive, transferable, and application-ready performance, not increasing device complexity.

The authors' abstract, as published at the source. Critical Reviews in Analytical Chemistry, 2026 · DOI ↗

TakeawaysPremium Ask the paperFree account

Continue with a free account

Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Electrochemistry

ElectrochemistryChemistry