Sports Medicine· 2026Q1· Review
Force and Power Testing in Anterior Cruciate Ligament Reconstruction Literature: A Scoping Review
- 0citations
- Q1SCImago
- 2026year
Short summary
A scoping review of 1625 studies found significant heterogeneity in force and power testing methods post-anterior cruciate ligament reconstruction (ACLR), with isokinetic dynamometry being the most common (64.9%) but current practices showing more variation than in the past.
AI-generated from the title and abstract; the full text is not read.
Key points
- 1625 studies were included in the scoping review on post-ACLR force and power testing.
- Isokinetic dynamometry (IKD) was the most common testing device (64.9%).
- Jump tests (32.2%) and force platforms (28.0%) were also frequently used.
- Significant heterogeneity exists in assessment device selection, metrics, and protocols.
- Force plate assessments demonstrated a linear increase in implementation since the surgical procedure.
AI-generated from the title and abstract; the full text is not read.
Abstract
Background Force and power testing has been recognised as a key aspect of anterior cruciate ligament reconstruction anterior cruciate ligament reconstruction (ACLR) rehabilitation. However, a literature synthesis is required to examine how these physical characteristics have been assessed due to pronounced heterogeneity in the methods used. Objectives To synthesise and describe the existing literature on force and power testing post-ACLR. Methods A scoping review of the electronic databases MEDLINE (PubMed), SPORTDiscus, Cochrane Library and PEDro was conducted including studies adopting at least one force or power test in patients post-ACLR. The search methodology followed the Joanna Briggs Institute Manual for evidence synthesis and included the Preferred Reporting Items for Systematic reviews and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR). Results In total, 1625 studies fulfilled the inclusion criteria. Seven main device categories were identified, with different rates of implementation over the years (1981–2023) and throughout the recovery process: (1) isokinetic dynamometry (IKD; 64.9%), (2) jump (without force platform; 32.2%), (3) force platform (28.0%), (4) traditional gym equipment and bodyweight exercises (6.2%), (5) hand-held dynamometry (4.0%), (6) manual muscle testing (1.5%) and (7) other devices (5.5%). Studies used 1.42 ± 0.62 devices, with 45 different combinations recorded. Various tests were conducted using different devices, ranging from 8 to 72 recorded tests per category. Only force plate assessments showed a linear increment in implementation from the surgical procedure ( r = 0.86, p = 0.012). Conclusions Significant heterogeneity in assessment device selection, metrics analysed, test implementation and protocols was observed. Most studies included a single device category to examine force and power characteristics of patients post-ACLR. The IKD remains the most adopted testing device in research, but current assessment practices are more varied than in the past.
The authors' abstract, as published at the source. Sports Medicine, 2026 · DOI ↗
Continue with a free account
Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Surgery
SurgeryMedicine