Equine Veterinary Journal· 2026Q1
Transverse intervertebral ratios of computed tomographic myelography of the caudal cervical spine (C5–C7) are a reliable diagnostic parameter in horses with ataxia caused by enlarged caudal intervertebral articular process joints
- 0citations
- Q1SCImago
- 2026year
Short summary
New ratios derived from computed tomographic myelography (CTM) of the caudal cervical spine (C5-C7) can reliably diagnose spinal cord compression in horses with ataxia. The contrast-enhanced cord area ratio (CE-CAR) showed significant differences between ataxic and control horses, with optimal cut-off values between 0.33 and 0.44.
AI-generated from the title and abstract; the full text is not read.
Key points
- New ratios, CCAR and CE-CAR, were developed from CTM images of the caudal cervical spine (C5-C7) in horses.
- Significant differences in CCAR and CE-CAR were found between horses with ataxia and healthy controls.
- The CE-CAR ratio can be used to identify clinically significant cervical cord compression, with optimal cut-off values identified.
- These ratios offer objective parameters for diagnosing spinal cord compression, improving diagnostic consistency.
AI-generated from the title and abstract; the full text is not read.
Abstract
Background Computed tomographic myelography (CTM) is increasingly used in horses with spinal ataxia. However, objective parameters for determining clinically significant spinal cord compression are lacking. Objectives To evaluate ratios on cross‐sectional CTM images as a diagnostic parameter for cervical spinal cord compression at the level of the caudal articular process joints. Study Design Retrospective, comparative cross‐sectional study. Methods Horses with spinal ataxia (Group A; n = 33) and control horses with no clinical evidence of neurologic disease (Group N; n = 19) were examined clinically and underwent CTM. On transverse images at the caudal articular process joints (APJs) of C5 to C7, the cord canal area ratio (CCAR), the contrast‐enhanced cord canal area ratio (CE‐CCAR), and the contrast‐enhanced cord area ratio (CE‐CAR) were calculated and compared between groups. Histopathological findings from post‐mortem (p.m.) examinations were included if the results were available. Results Significant differences were identified for CCAR (mean ratio A2: 0.21–0.22 vs. mean ratio N: 0.18–0.19; p = 0.01–0.04) and CE‐CAR (mean ratio A2: 0.36–0.4 vs. mean ratio N: 0.32–0.34; p = 0.005–0.01) at the caudal cervical spine between affected and control horses. Optimal cut‐off values to detect clinically significant cervical cord compression using CE‐CAR were between 0.33 and 0.44, with a sensitivity of 50% to 100% (95% confidence intervals [CIs] between 15% and 100%); and specificity of 42%–100% (95% CIs between 17% and 100%) when compared with p.m. examination results. Main Limitations Limited number of control horses and incomplete p.m. data to confirm spinal cord pathology for all cases. Conclusions The CE‐CAR supports the identification of cervical spinal cord compression and enhances consistency in objective image interpretation. It is a valuable ratio for determining the clinical significance of spinal cord compression in the caudal cervical spine using CTM.
The authors' abstract, as published at the source. Equine Veterinary Journal, 2026 · DOI ↗
Continue with a free account
Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Small AnimalsVeterinary