PofoliaDaily literature tracker

Journal of Sports Science and Medicine· 2026Q1

A Progressive 20m Shuttle Run Test to Estimate Maximum Oxygen Consumption in Ten Different Sports

Hyeong-Tae Kwon, Daeho Kim

Short summary

A new prediction model for maximal oxygen uptake (VO2max) using the 20-meter shuttle run test (20m-MST) demonstrates excellent validity and reliability for elite athletes across 10 sports, incorporating age, sex, and body weight into a single equation.

AI-generated from the title and abstract; the full text is not read.

Key points

  • A new VO2max prediction model using the 20m-MST was developed and validated for elite athletes across 10 sports.
  • The model incorporates age, sex, and body weight, achieving a multiple correlation coefficient of r = 0.833.
  • Validation showed excellent agreement with laboratory-measured VO2max, with an ICC of 0.901.
  • The 20m-MST results reflect a composite of VO2max, agility, and anaerobic capacity.

AI-generated from the title and abstract; the full text is not read.

Abstract

Cardiorespiratory fitness is a fundamental determinant of both health outcomes and athletic performance, and is most objectively quantified through maximal oxygen uptake (VO2max). Although laboratory-based graded exercise testing (GXT) with expired gas analysis remains the criterion method for VO2max assessment, its practical application is limited by cost, equipment requirements, and the time needed to evaluate large groups. To overcome these limitations, the 20-meter multistage shuttle run test (20m-MST) has emerged as one of the most widely adopted field-based tools due to its simplicity and capacity for simultaneous group assessment. However, existing VO2max prediction models based on the 20m-MST have largely been derived from small, sport-specific samples, limiting their generalizability to broader elite athletic populations. Therefore, the purpose of this study was to verify the validity of the 20m-MST and to develop a precise, field-applicable VO2max prediction model for elite athletes across a wide range of ages, sexes, and sports disciplines. A total of 564 elite athletes (males = 336, females = 228; age range: 13-35 years) were recruited from 10 sports disciplines. Each participant completed both the 20m-MST and a laboratory-based maximal GXT with concurrent expired gas analysis, with a minimum interval of one week maintained between the two assessments. The GXT was conducted using the KISS Protocol, with VO2max determined when at least two of five established physiological criteria were satisfied. Multiple regression analysis was conducted to develop a VO2max prediction equation using shuttle run lap count, age, sex, and body weight as predictor variables, and both the intraclass correlation coefficient (ICC) and Bland-Altman analysis were employed to evaluate the reliability and limits of agreement between predicted and measured values. Correlation analysis revealed a statistically significant positive correlation between VO2max and 20m-MST lap count across all subgroups (r = 0.700, p < 0.001). The regression model yielded a multiple correlation coefficient of r = 0.833, an explanatory power (R2) of 69.4%, and a standard error of estimate of 3.31 mL/kg/min. Validation demonstrated an ICC of r = 0.901, reflecting excellent agreement, with a mean difference of -0.031 ± 3.30 mL/kg/min and Bland-Altman limits of agreement of -0.17 ± 6.13% (95% CI: -0.30 to 0.24). The 20m-MST involves progressively increasing speed with repeated directional changes, indicating that both aerobic and anaerobic energy systems contribute to performance, and shuttle run results should therefore be interpreted as a composite indicator reflecting VO2max alongside agility and anaerobic capacity. The inclusion of age, sex, and body weight as predictor variables allows for VO2max estimation across both sexes and a broad age range within a single unified equation, representing a substantial improvement over previously reported models derived from limited samples. The developed prediction model demonstrated excellent validity and reliability, providing a practical and accurate tool for the assessment of cardiorespiratory endurance in elite athletes. Future research should consider refinements to the shuttle run protocol and the incorporation of correction factors for anaerobic energy contributions to further enhance the precision of VO2max estimation in diverse athletic populations.

The authors' abstract, as published at the source. Journal of Sports Science and Medicine, 2026 · DOI ↗

TakeawaysPremium Ask the paperFree account

Continue with a free account

Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Physiology

Physiology (medical)Medicine