PofoliaDaily literature tracker

Nature Medicine· 2026Q1

Performance of intracortical microelectrode arrays in people with implanted brain–computer interfaces over a 20-year period

Nick V. Hahn, Elias A. Stein, Benyamin Abramovich-Krasa, Jessica Abreu et al.

Short summary

Intracortical microelectrode arrays used in brain-computer interfaces (BCIs) for people with paralysis maintained functional performance over a median of 7.3 years, with an average of 35.6% of electrodes successfully recording neural spiking waveforms and a modest 7% decline over time.

AI-generated from the title and abstract; the full text is not read.

Key points

  • Intracortical microelectrode arrays in BCIs for paralysis maintained functionality over a median of 7.3 years.
  • An average of 35.6% of electrodes successfully recorded neural spiking waveforms.
  • Electrode functionality showed a modest decline of only 7 percentage points over the recording period.
  • 11 of 14 arrays provided meaningful movement decoding throughout participation.
  • Decoding accuracy increased logarithmically with the number of electrodes.

AI-generated from the title and abstract; the full text is not read.

Abstract

The silicon microelectrode ‘Utah’ array has enabled people with paralysis to control computer cursors, operate prosthetic limbs and communicate using high-performance brain–computer interfaces. However, reports so far have typically been limited to one or two individuals, with no systematic assessment of array longevity, decoding accuracy and day-to-day stability. Here we present a comprehensive 20-year evaluation of neural data from the BrainGate clinical trials, spanning 2,289 recording sessions, 20 arrays and 14 participants. On average, arrays successfully recorded neural spiking waveforms on 35.6% of electrodes, with a modest 7 percentage point decline over the recording period (up to 7.3 years). Using a ‘decoding signal-to-noise ratio’ (dSNR) metric, we found that 11 of 14 arrays provided meaningful movement decoding throughout participation (median dSNR >1), with three achieving >70% accuracy compared with able-bodied mouse control. We also found that dSNR increased approximately logarithmically with the number of electrodes, providing a pathway for scaling performance. While longevity exceeded previous nonhuman primate studies, achieving peak performance consistently may require further improvements.

The authors' abstract, as published at the source. Nature Medicine, 2026 · DOI ↗

TakeawaysPremium Ask the paperFree account

Continue with a free account

Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Cellular and Molecular Neuroscience

Cellular and Molecular NeuroscienceNeuroscience