Journal of Analytical Science & Technology· 2026Q2
Gıda Kaynaklı Bütün Bakterilerin Hassas Tespiti İçin Anahtar Peptit Kullanan MALDI-TOF MS Tabanlı İmmünoassay
MALDI-TOF MS–based immunoassay using switching peptide for sensitive detection of intact foodborne bacteria
- 0atıf
- Q2SCImago
- 2026yıl
Kısa özet
MALDI-TOF MS ve anahtar peptitler kullanan yeni bir homojen immünoassay, yıkama adımları olmadan beş gıda kaynaklı bakterinin (E. coli O157:H7, S. typhimurium, L. monocytogenes, S. aureus, B. cereus) hassas, kantitatif tespitini sağlar.
Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.
Ana noktalar
- MALDI-TOF MS kullanarak beş gıda kaynaklı bakteri (E. coli O157:H7, S. typhimurium, L. monocytogenes, S. aureus, B. cereus) için homojen bir immünoassay geliştirildi.
- Kantifikasyon, antijen-antikor bağlanması üzerine salınan ve kütle etiketleri görevi gören anahtar peptitlerin tespit edilmesiyle gerçekleştirilir.
- Deney, yıkama adımları olmadan homojen bir çözeltide çalışır.
- 0.01–10.00 pmol/µL aralığında iyi doğrusallık (R² > 0.983) ve floresan ve HPLC yöntemlerine kıyasla iyileştirilmiş hassasiyet gösterildi.
Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.
Özet (abstract)
Abstract A matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS)–based immunoassay was developed for quantitative detection of five foodborne bacterial species: Escherichia coli O157:H7, Salmonella typhimurium , Listeria monocytogenes , Staphylococcus aureus , and Bacillus cereus . The assay was conducted in a homogeneous solution without washing steps and enabled quantification through detection of switching peptides (antibody-binding peptides released upon antigen binding) released upon antigen–antibody binding, which served as mass tags for MALDI-TOF MS readout. Target-specific antibodies were isolated from commercially available unimmunized pig serum using a stepwise filtration approach involving target and filter bacteria, yielding 130.4 ± 20.0 µg and 95.2 ± 26.6 µg for the first and second isolated antibodies from 1 mL of pig serum ( n = 5), respectively. Quantitative analysis of the switching peptides using an internal standard (P14R) exhibited good linearity over the concentration range of 0.01–10.00 pmol/µL, with relative standard deviations of 1.4%–11.3% and coefficients of determination exceeding 0.983. Compared with fluorescence- and high-performance liquid chromatography–based methods, MALDI-TOF MS achieved a lower limit of detection, demonstrating improved sensitivity for detecting low-abundance bacterial targets. The developed immunoassay enabled quantitative detection of the five bacterial species at lower bacterial cell numbers per test than fluorescence-based assays.
Yazarların özeti; kaynağından alınmıştır. Journal of Analytical Science & Technology, 2026 · DOI ↗
Ücretsiz hesapla devam et
Makaleye Sor ile bu makaleye günde 3 soru ücretsiz; makaleyi kaydet, kaynakçasını al, ilgi alanına göre her gün yeni özetler. Çıkarımlar Premium.
Web'de ücretsiz devam etGoogle ya da Apple hesabınla giriş; kart istemez. Bu makaleye geri dönersin.
Telefonda:
Alan: Klinik Biyokimya
Clinical BiochemistryBiochemistry, Genetics and Molecular Biology