Journal of Neuroradiology· 2026Q1
Evaluating the Swallow-Tail Sign on susceptibility-weighted imaging (SWI) for Parkinson's disease diagnosis: A bivariate meta-analysis
- 0citations
- Q1SCImago
- 2026year
Short summary
The Swallow-Tail Sign (STS) on susceptibility-weighted imaging (SWI) shows high diagnostic accuracy for Parkinson's disease (PD), with pooled sensitivity of 0.91 and specificity of 0.89 across 17 studies.
AI-generated from the title and abstract; the full text is not read.
Key points
- The Swallow-Tail Sign (STS) on SWI has a pooled sensitivity of 0.91 (95% CI: 0.83-0.96) for diagnosing Parkinson's disease (PD).
- The pooled specificity of STS on SWI for PD diagnosis is 0.89 (95% CI: 0.82-0.93).
- The diagnostic odds ratio for STS on SWI in PD diagnosis is 83, with an area under the curve of 0.95.
- Seventeen studies comprising 1008 PD patients and 944 controls were included in the meta-analysis.
- Substantial heterogeneity was noted across the included studies.
AI-generated from the title and abstract; the full text is not read.
Abstract
BACKGROUND AND PURPOSE: The Swallow-Tail Sign (STS), reflecting nigrosome-1 integrity in the substantia nigra, is a magnetic resonance imaging biomarker for Parkinson's disease (PD). Although susceptibility-weighted imaging (SWI) is widely available, the diagnostic performance of STS on SWI has not been comprehensively quantified. This study evaluated the diagnostic accuracy of STS on SWI for identifying PD. MATERIALS AND METHODS: MEDLINE, Embase, and Web of Science were searched for studies assessing STS on SWI in adults with clinically diagnosed PD and healthy controls. Eligible studies provided data to construct 2 × 2 tables. Methodological quality was assessed with QUADAS-2. A bivariate random-effects model estimated pooled sensitivity, specificity, likelihood ratios, and diagnostic odds ratio. RESULTS: Seventeen studies including 1008 PD patients and 944 controls were analyzed. Pooled sensitivity was 0.91 (95% CI: 0.83-0.96) and specificity 0.89 (95% CI: 0.82-0.93). The positive likelihood ratio was 8.1 and the negative likelihood ratio 0.10. The diagnostic odds ratio was 83, and the area under the curve was 0.95. Substantial heterogeneity was observed without evidence of publication bias. CONCLUSIONS: STS on SWI demonstrates high diagnostic accuracy for PD and represents a reliable, non-invasive adjunct to clinical diagnosis.
The authors' abstract, as published at the source. Journal of Neuroradiology, 2026 · DOI ↗
Continue with a free account
Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Speech and Hearing
Speech and HearingHealth Professions