PofoliaShared via Pofolia

Nature Communications· 2012Q1

Intracellular temperature mapping with a fluorescent polymeric thermometer and fluorescence lifetime imaging microscopy

Kohki Okabe, Noriko Inada, Chie Gota, Yoshie Harada et al.

Short summary

Researchers developed the first method for mapping intracellular temperature using a fluorescent polymeric thermometer and fluorescence lifetime imaging microscopy, achieving 200 nm spatial resolution and 0.18–0.58 °C temperature resolution.

AI-generated from the title and abstract; the full text is not read.

Key points

  • Developed the first method for intracellular temperature mapping.
  • Utilized a fluorescent polymeric thermometer and fluorescence lifetime imaging microscopy.
  • Achieved 200 nm spatial resolution and 0.18–0.58 °C temperature resolution.
  • Observed higher temperatures in the nucleus and centrosome compared to the cytoplasm.
  • Detected localized heat production from mitochondria.

AI-generated from the title and abstract; the full text is not read.

Abstract

Cellular functions are fundamentally regulated by intracellular temperature, which influences biochemical reactions inside a cell. Despite the important contributions to biological and medical applications that it would offer, intracellular temperature mapping has not been achieved. Here we demonstrate the first intracellular temperature mapping based on a fluorescent polymeric thermometer and fluorescence lifetime imaging microscopy. The spatial and temperature resolutions of our thermometry were at the diffraction limited level (200 nm) and 0.18–0.58 °C. The intracellular temperature distribution we observed indicated that the nucleus and centrosome of a COS7 cell, both showed a significantly higher temperature than the cytoplasm and that the temperature gap between the nucleus and the cytoplasm differed depending on the cell cycle. The heat production from mitochondria was also observed as a proximal local temperature increase. These results showed that our new intracellular thermometry could determine an intrinsic relationship between the temperature and organelle function. Intracellular temperature mapping has not previously been achieved. Now, a fluorescent polymeric thermometer has been developed that can be used in combination with fluorescence-lifetime imaging microscopy to allow thermometry with spatial and temperature resolutions of 200 nm and 0.18–0.58 ° C.

The authors' abstract, as published at the source. Nature Communications, 2012 · DOI ↗

TakeawaysPremium
Ask the paperFree account

Continue with a free account

Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Physical and Theoretical Chemistry

Physical and Theoretical ChemistryChemistry