Analytical Chemistry· 2026Q1
Adaptive Approach Strategy for Efficient Scanning Ion Conductance Microscopy Based on Non-monotonic Approach Curves
- 0citations
- Q1SCImago
- 2026year
Short summary
An adaptive two-stage approach strategy for Scanning Ion Conductance Microscopy (SICM) significantly increases scanning speed (up to 3.02x) and improves accuracy (MSE 62.4% of conventional) by modulating nanopipette velocity based on non-monotonic approach curves.
AI-generated from the title and abstract; the full text is not read.
Key points
- Introduced a two-stage adaptive approach strategy for SICM utilizing non-monotonic approach curves.
- The strategy modulates nanopipette velocity based on proximity to the sample surface.
- Achieved up to 3.02x higher average pixel rates on PDMS substrates compared to conventional methods.
- Reduced mean square error to 62.4% of the conventional value on PDMS substrates.
- Validated through simulations, theoretical calculations, and experiments on PDMS and fixed macrophages/MCF-7 cells.
AI-generated from the title and abstract; the full text is not read.
Abstract
Abstract Scanning ion conductance microscopy (SICM) enables high-resolution, noncontact, in situ characterization of specimens in liquid environments, providing simultaneous access to three-dimensional (3D) topographical, electrical, and mechanical properties. Despite its versatility, the inherent imaging principle limits scanning speed, presenting a significant challenge to further development. This work introduces an adaptive scanning strategy leveraging the distinctive nonmonotonic (“rise-then-fall”) approach curve observed in asymmetric self-referenced SICM (ASR-SICM). By employing a two-stage approach strategy, the nanopipette modulates its velocity based on its proximity to the sample surface, thereby enhancing both temporal resolution and imaging fidelity. The effectiveness of the proposed method was evaluated through finite element simulations and theoretical calculations, where the influences of electrolyte configuration and nanopipette structural parameters on the approach curve and feedback range were systematically analyzed. Additionally, the impact of different threshold settings on scanning time was examined. Subsequently, approach curves under different electrolyte conditions were measured on PDMS substrates, and the imaging accuracy was evaluated using fixed macrophages. Finally, comparative experiments on micropatterned polydimethylsiloxane (PDMS) substrates and MCF-7 cells demonstrate that the proposed method achieves equivalent average pixel rates up to 3.02 times and 1.85 times that of the conventional method, respectively, with the mean square error (MSE) on PDMS as low as 62.4% of the conventional value. These findings validate the potential of the adaptive scanning approach to overcome the scanning speed limitations of SICM, improving both imaging efficiency and quality.
The authors' abstract, as published at the source. Analytical Chemistry, 2026 · DOI ↗
Continue with a free account
Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Electrochemistry
ElectrochemistryChemistry