PofoliaShared via Pofolia

Journal of Performance of Constructed Facilities· 2013Q2

Application of Liquid Nitrogen Freezing to Recovery of a Collapsed Shield Tunnel

Xiangdong Hu, Wang Guo, Luoyu Zhang, Jintai Wang

Short summary

Liquid nitrogen freezing, supplemented by brine freezing, was successfully used to recover a collapsed Nanjing Metro tunnel, demonstrating faster cooling, lower temperatures, and a wider frozen range compared to traditional brine freezing.

AI-generated from the title and abstract; the full text is not read.

Key points

  • Liquid nitrogen freezing was employed for the second recovery of a collapsed Nanjing Metro tunnel after an initial collapse and subsequent water/sand leakage.
  • Real-time temperature data from an informatized system analyzed the freezing effect at each stage.
  • Liquid nitrogen freezing exhibited advantages over brine freezing, including faster cooling, lower temperatures, and a wider frozen range.
  • The freezing scheme was deemed safe and rational, leading to the successful reconnection of the collapsed tunnel section.

AI-generated from the title and abstract; the full text is not read.

Abstract

An accident involving the collapse of a running tunnel along the Nanjing Metro (Jiangsu Province, P. R. China) occurred as the tunneling shield arrived at the receiving shaft. The brine freezing method was used for the recovery of the collapsed tunnel. During the recovery project, another collapse resulting in the leakage of water and sand occurred. By considering the tight construction schedule, the freezing method was also used for the second recovery. Liquid nitrogen freezing was adopted as the primary process and supplemented by brine freezing. On the basis of the real-time variation of the frozen soil temperature, which was obtained through an informatized construction system, this study analyzes the freezing effect at each construction stage of the second recovery and identifies the advantages of liquid nitrogen freezing over brine freezing. It also evaluates the safety and rationality of the freezing scheme. The successful completion of each construction stage and reconnection of the collapsed section of the metro tunnel are described. Compared with brine freezing, liquid nitrogen freezing is shown to have the advantages of faster cooling, lower temperature, and wider frozen range. The freezing construction scheme of the second recovery project was safe, but it should be more economical. To reduce the engineering cost, it is necessary to fully utilize the advantages of liquid nitrogen in other freezing projects.

The authors' abstract, as published at the source. Journal of Performance of Constructed Facilities, 2013 · DOI ↗

TakeawaysPremium
Ask the paperFree account

Continue with a free account

Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: General Engineering

General EngineeringEngineering