PofoliaShared via Pofolia

Scientific Reports· 2026Q1

Encoder-controlled functional electrical stimulator for stroke rehabilitation: a usability study

Cassandra D Solomons, V. Shanmugasundaram, Selvaraj Samuelkamaleshkumar, Suresh Annpatriciacatherine et al.

Short summary

A novel encoder-controlled functional electrical stimulator (EC-FES) that mirrors unaffected wrist movements to the stroke-affected wrist achieved high usability scores (SUS: 74 ± 16.3, patient questionnaire: 78.26 ± 8.54) in a preliminary study with 20 stroke patients and 15 therapists.

AI-generated from the title and abstract; the full text is not read.

Key points

  • A novel EC-FES device was tested for usability in stroke rehabilitation.
  • The device uses unaffected wrist movement to control electrical stimulation on the affected wrist, creating mirrored activity.
  • 20 stroke patients and 15 therapists participated in a single-session usability study.
  • Patients reported high usability (SUS: 74 ± 16.3) and user experience, with a patient questionnaire score of 78.26 ± 8.54.
  • Therapists also provided positive feedback, with a mean score of 75.3 ± 14.93.

AI-generated from the title and abstract; the full text is not read.

Abstract

Numerous therapeutic interventions have been explored for stroke related dysfunctions with various degrees of success; however, rehabilitation of the stroke-affected upper limb and hand still remains a challenge. Focus has now shifted to rehabilitative training devices that augment neuroplasticity and improve motor control. This article discusses a usability study carried out on a novel device called the encoder-controlled FES. It uses flexion and extension of the unaffected wrist to control the delivery of stimulation to the stroke affected wrist, resulting in a mirrored activity of the unaffected wrist on the stroke-affected wrist. The hypothesis was that a combination of bilateral arm training and FES mediated mirrored wrist activity will help the brain to relearn the activity and improve motor control. A preliminary usability study was conducted to check the acceptability of the device being used in a clinical setting. The device was used by 20 patients with stroke and 15 occupational/physiotherapists in a single session each. After the session, patients filled in three feedback forms – the System Usability Scale (SUS), the User Experience Questionnaire (UEQ) and an EC-FES patient questionnaire; the therapists were given an EC-FES therapist questionnaire. The mean scores obtained for the SUS test and patient questionnaire were 74 ± 16.3, and 78.26 ± 8.54 respectively. All the questions in the UEQ were answered positively, conveying that the device meets participants expectations, and the mean score obtained for the therapist questionnaire was 75.3 ± 14.93. The scores suggest that the device may be useable in a clinical setting and paves the way for further definitive trials.

The authors' abstract, as published at the source. Scientific Reports, 2026 · DOI ↗

TakeawaysPremium
Ask the paperFree account

Continue with a free account

Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Rehabilitation

RehabilitationMedicine