New England Journal of Medicine· 2014Q1
Transcatheter Aortic-Valve Replacement with a Self-Expanding Prosthesis
- 2,895citations
- Q1SCImago
- 2014year
Short summary
Transcatheter aortic-valve replacement (TAVR) with a self-expanding prosthesis resulted in a significantly lower rate of death from any cause at 1 year (14.2%) compared to surgical aortic-valve replacement (19.1%) in patients with severe aortic stenosis and increased surgical risk.
AI-generated from the title and abstract; the full text is not read.
Key points
- TAVR with a self-expanding prosthesis led to a 4.9% absolute reduction in 1-year mortality compared to surgical valve replacement in high-risk patients (14.2% vs. 19.1%).
- The study included 795 patients with severe aortic stenosis at increased surgical risk, randomized 1:1 to TAVR or surgery.
- TAVR met noninferiority criteria for valve function, functional status, and quality of life.
- Exploratory analyses indicated a reduction in major adverse cardiovascular events with TAVR and no increase in stroke risk.
AI-generated from the title and abstract; the full text is not read.
Abstract
BACKGROUND: We compared transcatheter aortic-valve replacement (TAVR), using a self-expanding transcatheter aortic-valve bioprosthesis, with surgical aortic-valve replacement in patients with severe aortic stenosis and an increased risk of death during surgery. METHODS: We recruited patients with severe aortic stenosis who were at increased surgical risk as determined by the heart team at each study center. Risk assessment included the Society of Thoracic Surgeons Predictor Risk of Mortality estimate and consideration of other key risk factors. Eligible patients were randomly assigned in a 1:1 ratio to TAVR with the self-expanding transcatheter valve (TAVR group) or to surgical aortic-valve replacement (surgical group). The primary end point was the rate of death from any cause at 1 year, evaluated with the use of both noninferiority and superiority testing. RESULTS: A total of 795 patients underwent randomization at 45 centers in the United States. In the as-treated analysis, the rate of death from any cause at 1 year was significantly lower in the TAVR group than in the surgical group (14.2% vs. 19.1%), with an absolute reduction in risk of 4.9 percentage points (upper boundary of the 95% confidence interval, -0.4; P<0.001 for noninferiority; P = 0.04 for superiority). The results were similar in the intention-to-treat analysis. In a hierarchical testing procedure, TAVR was noninferior with respect to echocardiographic indexes of valve stenosis, functional status, and quality of life. Exploratory analyses suggested a reduction in the rate of major adverse cardiovascular and cerebrovascular events and no increase in the risk of stroke. CONCLUSIONS: In patients with severe aortic stenosis who are at increased surgical risk, TAVR with a self-expanding transcatheter aortic-valve bioprosthesis was associated with a significantly higher rate of survival at 1 year than surgical aortic-valve replacement. (Funded by Medtronic; U.S. CoreValve High Risk Study ClinicalTrials.gov number, NCT01240902.).
The authors' abstract, as published at the source. New England Journal of Medicine, 2014 · DOI ↗
Continue with a free account
Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Cardiology and Cardiovascular Medicine
Cardiology and Cardiovascular MedicineMedicine