PofoliaShared via Pofolia

Scientific Reports· 2026Q1

HemaViT: transformer-based deep learning for automated non-invasive anemia detection using conjunctival imaging

Gourishetty Sindhusha, Rupesh K. Mishra, R. Jegadeesan

Short summary

HemaViT, a novel transformer-based deep learning framework, achieves 95.8% average accuracy for automated, non-invasive anemia detection using conjunctival images.

AI-generated from the title and abstract; the full text is not read.

Key points

  • HemaViT framework combines Dual-Attention PSPNet, FPN with MFE, Vision Transformer (ViT), and IWPA for anemia detection.
  • Achieved 95.8% average accuracy, 97.6% precision, 96.9% recall, and 0.98 AUC-ROC on the Eyes Defy Anemia dataset (1,320 images).
  • Outperformed ResNet50, DenseNet121, EfficientNet-B0, MobileNetV3, and a CNN+RNN hybrid model.
  • Ablation studies confirmed the effectiveness of its core components: segmentation, multi-scale features, transformer learning, and hyperparameter optimization.

AI-generated from the title and abstract; the full text is not read.

Abstract

Abstract Anemia is a common hematological disorder that requires timely diagnosis to reduce the risk of severe health complications, particularly in resource-limited healthcare settings. This study proposes HemaViT, a transformer-based deep learning framework for automated, non-invasive detection of anemia from conjunctival images. The proposed framework integrates Dual-Attention PSPNet for accurate conjunctiva segmentation, a Feature Pyramid Network (FPN) with Multiscale Feature Exposure (MFE) for hierarchical feature extraction, a Vision Transformer (ViT) for global contextual representation, and the Improved Waterwheel Plant Algorithm (IWPA) for automated hyperparameter optimization. Experiments were conducted on the publicly available Eyes Defy Anemia dataset, which contains 1,320 conjunctival images, using stratified five-fold cross-validation. HemaViT achieved an average accuracy of 95.8%, precision of 97.6%, recall of 96.9%, F1-score of 97.2%, specificity of 98.7%, and an AUC-ROC of 0.98. Comparative experiments demonstrated that the proposed framework consistently outperformed widely used deep learning models, including ResNet50, DenseNet121, EfficientNet-B0, MobileNetV3, and a CNN + RNN hybrid model, while maintaining a favorable balance between classification performance and computational complexity. Ablation studies further confirmed the contributions of conjunctiva segmentation, multi-scale feature extraction, transformer-based contextual learning, and IWPA-driven hyperparameter optimization to the overall performance. Although additional validation on larger, more diverse clinical datasets is required, the proposed framework demonstrates strong potential for automated, non-invasive anemia screening in mobile health and resource-constrained clinical environments.

The authors' abstract, as published at the source. Scientific Reports, 2026 · DOI ↗

TakeawaysPremium
Ask the paperFree account

Continue with a free account

Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Hematology

HematologyMedicine