Lasers in Medical Science· 2017Q2
Effect of wavelength and beam width on penetration in light-tissue interaction using computational methods
- 1,038citations
- Q2SCImago
- 2017year
Short summary
Computational modeling reveals that light penetration depth in tissue increases with wavelength, reaching up to 5378 μm. A 10-mm beam width delivers 73-88% of the fluence at 1-3 mm depths compared to an infinitely wide beam, indicating limited benefit from larger spot sizes for deeper penetration.
AI-generated from the title and abstract; the full text is not read.
Key points
- Light penetration depth in tissue increases with wavelength, reaching up to 5378 μm.
- A 10-mm beam width delivers 73-88% of the fluence at 1-3 mm depths compared to an infinitely wide beam.
- Larger beam widths provide diminishing returns for increasing light penetration depth.
- Wavelength and illumination geometry significantly influence fluence distribution and treatment efficacy.
AI-generated from the title and abstract; the full text is not read.
Abstract
Penetration depth of ultraviolet, visible light and infrared radiation in biological tissue has not previously been adequately measured. Risk assessment of typical intense pulsed light and laser intensities, spectral characteristics and the subsequent chemical, physiological and psychological effects of such outputs on vital organs as consequence of inappropriate output use are examined. This technical note focuses on wavelength, illumination geometry and skin tone and their effect on the energy density (fluence) distribution within tissue. Monte Carlo modelling is one of the most widely used stochastic methods for the modelling of light transport in turbid biological media such as human skin. Using custom Monte Carlo simulation software of a multi-layered skin model, fluence distributions are produced for various non-ionising radiation combinations. Fluence distributions were analysed using Matlab mathematical software. Penetration depth increases with increasing wavelength with a maximum penetration depth of 5378 μm calculated. The calculations show that a 10-mm beam width produces a fluence level at target depths of 1-3 mm equal to 73-88% (depending on depth) of the fluence level at the same depths produced by an infinitely wide beam of equal incident fluence. Meaning little additional penetration is achieved with larger spot sizes. Fluence distribution within tissue and thus the treatment efficacy depends upon the illumination geometry and wavelength. To optimise therapeutic techniques, light-tissue interactions must be thoroughly understood and can be greatly supported by the use of mathematical modelling techniques.
The authors' abstract, as published at the source. Lasers in Medical Science, 2017 · DOI ↗
Continue with a free account
Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Dermatology
DermatologyMedicine