Influence of curing modes and simulated oral environments on the sorption of silane-containing self-adhesive resin cements: an in vitro study

Jirawat Choengbunluesak, Wisarut Prawatvatchara, Awiruth Klaisiri, Tool Sriamporn et al.

Short summary

Dual-curing significantly reduced fluid sorption in silane-containing self-adhesive resin cements compared to auto-curing, with ethanol and lactic acid increasing uptake, especially under auto-curing.

AI-generated from the title and abstract; the full text is not read.

Key points

  • Dual-curing resulted in lower fluid sorption than auto-curing across all tested immersion media.
  • Immersion in 20% ethanol and 0.01 M lactic acid generally increased fluid sorption compared to distilled water.
  • A significant three-way interaction between cement type, curing mode, and immersion medium influenced fluid sorption (p=0.002).
  • Dual-cured PANAVIA SA Luting Multi in distilled water showed the lowest sorption (26.27 ± 0.97 µg/mm³).

AI-generated from the title and abstract; the full text is not read.

Abstract

This in vitro study evaluated the effects of curing mode and immersion medium on the fluid sorption of two silane-containing self-adhesive resin cements. Disk-shaped specimens (15 mm × 1 mm) of BeautiLink SA and PANAVIA SA Luting Multi were prepared using an ISO 4049:2019-based protocol. Specimens were polymerized using either dual-curing or auto-curing mode and then immersed in distilled water, 20% ethanol, or 0.01 M lactic acid ( n = 10 per group) for 7 days at 37 °C. Fluid sorption was calculated in µg/mm³.Data were analyzed using three-way analysis of variance (ANOVA; resin cement × curing mode × immersion medium) and Tukey’s honestly significant difference (HSD) post hoc test (α = 0.05); a container-level sensitivity analysis was also performed to assess robustness to within-container clustering. A significant three-way interaction among resin cement, curing mode, and immersion medium was observed for fluid sorption ( p = 0.002). Mean sorption values were lower for dual-cured than for auto-cured specimens across all matching immersion conditions. Under auto-curing, mean sorption values in 20% ethanol and 0.01 M lactic acid were generally higher than the corresponding distilled-water values. Dual-cured PANAVIA SA Luting Multi immersed in distilled water yielded the lowest numerical sorption value (26.27 ± 0.97 µg/mm³). The three-way interaction remained significant in the container-level sensitivity analysis ( p = 0.012). Dual-curing was associated with lower mean fluid sorption overall in the tested silane-containing self-adhesive resin cements, although the magnitude of the difference depended on cement formulation and immersion medium. Ethanol and lactic acid generally increased fluid uptake, particularly under auto-curing. Distilled-water sorption values were below the ISO 4049 water-sorption threshold; however, because water solubility was not evaluated, overall ISO 4049 compliance cannot be claimed from sorption data alone. Ethanol- and lactic-acid sorption values should be interpreted as modified solvent/acid challenge outcomes rather than direct ISO-compliance data.

The authors' abstract, as published at the source. BMC Oral Health, 2026 · DOI ↗

TakeawaysPremium
Ask the paperFree account

Continue with a free account

Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Orthodontics

OrthodonticsDentistry