PofoliaShared via Pofolia

Medical Physics· 2018Q1

Automatic treatment planning based on three‐dimensional dose distribution predicted from deep learning technique

Jiawei Fan, Jiazhou Wang, Zhi Chen, Chaosu Hu et al.

Short summary

A deep learning model accurately predicts clinically acceptable 3D dose distributions for IMRT radiotherapy, enabling automated treatment plan generation with no statistically significant differences from manual plans for most metrics.

AI-generated from the title and abstract; the full text is not read.

Key points

  • A deep learning model predicts 3D dose distributions for IMRT radiotherapy based on patient CT images, organ contours, and prescription doses.
  • The model achieved clinically acceptable dose predictions, with no statistically significant differences from real clinical plans for most DVH indices in 50 test cases.
  • An automated plan generation algorithm, using the predicted dose distributions, produced plans with clinically acceptable differences compared to predicted plans.

AI-generated from the title and abstract; the full text is not read.

Abstract

Purpose To develop an automated treatment planning strategy for external beam intensity‐modulated radiation therapy ( IMRT ), including a deep learning‐based three‐dimensional (3D) dose prediction and a dose distribution‐based plan generation algorithm. Methods and Materials A residual neural network‐based deep learning model is trained to predict a dose distribution based on patient‐specific geometry and prescription dose. A total of 270 head‐and‐neck cancer cases were enrolled in this study, including 195 cases in the training dataset, 25 cases in the validation dataset, and 50 cases in the testing dataset. All patients were treated with IMRT with a variety of different prescription patterns. The model input consists of CT images and contours delineating the organs at risk ( OAR s) and planning target volumes ( PTV s). The algorithm output is trained to predict the dose distribution on the CT image slices. The obtained prediction model is used to predict dose distributions for new patients. Then, an optimization objective function based on these predicted dose distributions is created for automatic plan generation. Results Our results demonstrate that the deep learning method can predict clinically acceptable dose distributions. There is no statistically significant difference between prediction and real clinical plan for all clinically relevant dose–volume histogram ( DVH ) indices, except brainstem, right and left lens. However, the predicted plans were still clinically acceptable. The results of plan generation show no statistically significant differences between the automatic generated plan and the predicted plan except PTV 70.4 , but the difference is only 0.5% which is still clinically acceptable. Conclusion This study developed a new automated radiotherapy treatment planning system based on 3D dose prediction and 3D dose distribution‐based optimization. It is a promising approach for realizing automated treatment planning in the future.

The authors' abstract, as published at the source. Medical Physics, 2018 · DOI ↗

TakeawaysPremium
Ask the paperFree account

Continue with a free account

Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Radiation

RadiationPhysics and Astronomy