Anesthesia & Analgesia· 2018Q1
Diagnostic Accuracy of Point-of-Care Gastric Ultrasound
- 161citations
- Q1SCImago
- 2018year
Short summary
Point-of-care gastric ultrasound accurately detects a "full stomach" with 100% sensitivity and 97.5% specificity in a simulated clinical scenario.
AI-generated from the title and abstract; the full text is not read.
Key points
- Point-of-care gastric ultrasound has a sensitivity of 1.0 (95% CI, 0.925-1.0) and specificity of 0.975 (95% CI, 0.95-1.0) for detecting a full stomach.
- The method yielded a positive likelihood ratio of 40.0 and a negative likelihood ratio of 0.
- The study involved 40 healthy volunteers randomized to fasted or fed states over 80 study sessions.
- A "full stomach" was defined as any solid content or >1.5 mL/kg of clear fluid.
AI-generated from the title and abstract; the full text is not read.
Abstract
BACKGROUND: Pulmonary aspiration of gastric contents is associated with significant perioperative morbidity and mortality. Previous studies have investigated the validity, reliability, and possible clinical impact of gastric ultrasound for the assessment of gastric content at the bedside. In the present study, we examined the accuracy (evaluated as sensitivity, specificity, and likelihood ratios) of point-of-care gastric ultrasound to detect a "full stomach" in a simulated scenario of clinical equipoise. METHODS: After a minimum fasting period of 8 hours, 40 healthy volunteers were randomized in a 1:1 ratio to either remain fasted or ingest a standardized quantity of clear fluid or solid. Each subject was randomized twice on 2 independent study sessions at least 24 hours apart. A gastric ultrasound examination was performed by a blinded sonographer following a standardized scanning protocol. Using a combination of qualitative and quantitative findings, the result was summarized in a dichotomous manner as positive (any solid or >1.5 mL/kg of clear fluid) or negative (no solid and ≤1.5 mL/kg of clear fluid) for full stomach. RESULTS: Data from 80 study sessions were analyzed. In this simulated clinical scenario with a pretest probability of 50%, point-of-care gastric ultrasound had a sensitivity of 1.0 (95% confidence interval [CI], 0.925-1.0), a specificity of 0.975 (95% CI, 0.95-1.0), a positive likelihood ratio of 40.0 (95% CI, 10.33-∞), a negative likelihood ratio of 0 (95% CI, 0-0.072), a positive predictive value of 0.976 (95% CI, 0.878-1.0), and a negative predictive value of 1.0 (95% CI, 0.92-1.0). CONCLUSIONS: Our results suggest that bedside gastric ultrasound is highly sensitive and specific to detect or rule out a full stomach in clinical scenarios in which the presence of gastric content is uncertain.
The authors' abstract, as published at the source. Anesthesia & Analgesia, 2018 · DOI ↗
Continue with a free account
Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Critical Care and Intensive Care Medicine
Critical Care and Intensive Care MedicineMedicine