Analytical Chemistry· 2026Q1
CAMM-Based Rational Hapten Design for Monoclonal Antibodies with Different Specificities against Avermectins and a Sensitive Chemiluminescence Immunoassay
- 0citations
- Q1SCImago
- 2026year
Short summary
Computer-aided molecular modeling (CAMM) guided the design of four haptens, leading to monoclonal antibodies (mAbs) with tailored specificities against avermectins (AVMs). A broadly reactive mAb (A1) detected five AVMs with IC50s as low as 3.3 ng/mL, while a class-selective mAb (A2) recognized three AVMs with IC50s as low as 3.5 ng/mL. A chemiluminescence immunoassay using mAb A1 achieved regulatory-level detection limits in milk.
AI-generated from the title and abstract; the full text is not read.
Key points
- CAMM identified macrocyclic lactone and glycosidic linkage as key antigenic determinants for avermectins.
- Four rationally designed haptens produced mAbs with broad-spectrum (A1) and class-selective (A2) recognition of avermectins.
- mAb A1 detected five avermectins with IC50 values between 3.3 and 18.9 ng/mL.
- mAb A2 showed preferential recognition of abamectin B1a, emamectin, and eprinomectin with IC50s between 3.5 and 4.6 ng/mL.
- A chemiluminescence immunoassay using mAb A1 achieved regulatory-level detection limits in milk samples.
AI-generated from the title and abstract; the full text is not read.
Abstract
Abstract Computer-aided molecular modeling (CAMM) has become an important tool for guiding rational hapten design. Avermectins are a family of macrocyclic lactones with highly similar structures, making monoclonal antibody (mAb) specificity difficult to control. In this work, we used CAMM to analyze the antigenic determinant of avermectin (AVMs), and showed that the macrocyclic lactone and glycosidic linkage are highly reactive. Based on these findings, four haptens (H1−H4) were rationally designed and used to produce mAbs for AVMs. The broadly reactive mAb A1 showed high sensitivity for abamectin B1a, emamectin, eprinomectin, ivermectin, and doramectin, with IC50 values of 5.6, 3.3, 5.1, 13.3, and 18.9 ng/mL, respectively. In contrast, the class-selective mAb A2 showed preferential recognition of abamectin B1a, emamectin, and eprinomectin, with IC50 values of 3.5, 3.8, and 4.6 ng/mL, respectively. Further CAMM analysis indicated that H-Gly42 may contribute to the broad-spectrum recognition of AVMs, whereas exposure of the macrocyclic lactone ring may influence whether the resulting mAbs exhibit broad-spectrum or class-selective recognition. Using mAb A1, a fully automated chemiluminescence enzyme immunoassay was developed, achieving detection limits that met regulatory requirements. In milk samples, the assay showed recoveries of 84.5-104.0% and good accuracy and stability, supporting its application for the rapid detection of AVM residues in dairy products.
The authors' abstract, as published at the source. Analytical Chemistry, 2026 · DOI ↗
Continue with a free account
Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Food Science
Food ScienceAgricultural and Biological Sciences