Annals of Laboratory Medicine· 2026Q1
Nationwide Survey of Laboratory-Initiated Peripheral Blood Smear Review Practices in Korea: Criteria, Workload, and Reimbursement
- 0citations
- Q1SCImago
- 2026year
Short summary
A 2025 survey of 103 Korean institutions found that 94.1% use predefined criteria for laboratory-initiated peripheral blood smear reviews (LIRs), with analyzer flags (95.8%) and CBC parameters (85.4%) being most common. Technologists bear the primary workload (median 4,825 min/month in large centers), and most institutions (79.4%) do not seek reimbursement for these reviews.
AI-generated from the title and abstract; the full text is not read.
Key points
- 94.1% of 103 surveyed Korean institutions use predefined criteria for laboratory-initiated peripheral blood smear reviews (LIRs).
- Analyzer-generated flags (95.8%) and CBC parameters (85.4%) are the most frequently used LIR criteria.
- Technologists handle the majority of the LIR workload, with a median of 4,825 minutes per month in large academic centers.
- 79.4% of participating institutions do not claim reimbursement for LIRs.
- Compared to 2010, supplementary criteria like reticulocyte count and clinical information are used less frequently.
AI-generated from the title and abstract; the full text is not read.
Abstract
Background: Peripheral blood (PB) smear review is an essential component of the diagnostic workup for hematological disorders. Laboratory-initiated PB smear reviews (LIRs) are performed based on predefined criteria involving complete blood count (CBC) parameters, analyzer-generated flags, and clinical information. However, nationwide data on LIR practices, workloads, and reimbursements are limited. Therefore, we investigated the status of LIR practices in Korean institutions. Methods: A nationwide survey of medical institutions in South Korea was conducted between October and November 2025. Responses covering LIR criteria, analyzer flag utilization, workload, reporting, and reimbursements were collected from 103 institutions. Workload was assessed using case- and time-based approaches. Results: Among the participating institutions, 94.1% used predefined LIR criteria. Analyzer-generated flags were the most frequently applied criteria (95.8%), followed by CBC (85.4%) and automated differential count (85.4%) parameters. Compared with the 2010 Korean nationwide survey, supplementary criteria for reticulocyte count, clinical information, and delta checks were less frequently used. The numerical thresholds exhibited notable inter-institutional variability. The operational burden was concentrated on technologist-performed workflows, with median monthly times of 4,825 and 575 min for technologists and hematology specialists in large academic centers, respectively. Most institutions (79.4%) did not claim reimbursements for LIRs. Conclusions: LIR practices in Korea have evolved toward simpler, analyzer-centered workflows; however, variability persists in terms of review criteria, workload, reporting, and reimbursements. Therefore, updated consensus recommendations and reimbursement policies are required.
The authors' abstract, as published at the source. Annals of Laboratory Medicine, 2026 · DOI ↗
Continue with a free account
Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Medical Laboratory TechnologyHealth Professions