Energies· 2026Q1
Demand-Profile Effects on PV Self-Consumption and Battery Storage Performance: Five Mediterranean Case Studies
- 0citations
- Q1SCImago
- 2026year
Short summary
Simulations show that without battery storage, photovoltaic (PV) systems cover 36.1–67.3% of annual demand across five diverse consumer profiles (university, aquarium, industrial, residential, travel agency) in Crete, Greece. With optimized PV and battery sizing, demand coverage can reach 89.5–94.6%, but surplus electricity can range from 20.1–77.1%.
AI-generated from the title and abstract; the full text is not read.
Key points
- PV systems without battery storage covered 36.1–67.3% of annual demand across five consumer profiles.
- Optimized PV and battery configurations achieved 89.5–94.6% demand coverage with 20.1–77.1% surplus generation.
- PV capacity increases provided diminishing returns in demand coverage for residential settings.
- PV degradation affects direct supply, while battery degradation reduces total coverage.
- Economic outcomes were most sensitive to electricity purchase price and demand levels.
AI-generated from the title and abstract; the full text is not read.
Abstract
This study evaluates photovoltaic (PV) self-production with and without battery energy storage for five contrasting consumer profiles under the meteorological conditions considered for Crete, Greece: a university campus, an aquarium, an industrial facility, a residential group and a travel agency. Annual chronological simulations at hourly resolution assess demand coverage, surplus generation and economic performance over a 25-year evaluation period, with no revenue assigned to surplus electricity. The model includes battery charging and discharging power limits, annual degradation rates of 0.5% for PV power capacity and 2% for battery energy capacity, and equipment replacement assumptions. Normalised generation and storage parameters facilitate comparison across cases. A one-at-a-time sensitivity analysis examines six technical and economic parameters for one selected configuration per consumer. Without storage, the tested configurations supply 36.1–45.8% of annual demand at the university, 36.5% at the aquarium, 47.7–67.3% at the industrial facility, 24.2–29.2% in the residential group and 50.2–55.1% at the travel agency. Among the reported configurations, those achieving the highest mean annual demand coverage in each case supply 89.5–94.6% of demand, while retaining surplus fractions of 20.1–77.1%. In the residential case, increasing PV capacity from 500 to 1000 kW at a fixed storage capacity of 1000 kWh raises coverage by only 2.6 percentage points, while surplus increases from 55.3% to 77.1%. Degradation affects useful supply differently from nominal asset performance: surplus generation buffers the decline in direct PV supply, whereas battery degradation generally drives the reduction in total coverage. Economic outcomes are particularly sensitive to electricity purchase price and demand level, with the residential and travel agency configurations showing greater dependence on favorable economic assumptions. The findings support joint PV–battery sizing based on demand timing and marginal useful energy gains, rather than annual energy matching or maximum coverage alone.
The authors' abstract, as published at the source. Energies, 2026 · DOI ↗
Continue with a free account
Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Energy Engineering and Power Technology
Energy Engineering and Power TechnologyEnergy