Scientific Reports· 2026Q1
Efficient infrared radiation calibration method for wide dynamic range infrared radiation measurement systems
- 0citations
- Q1SCImago
- 2026year
Short summary
A new infrared radiation calibration method integrates variable optical attenuator and adjustable integration time, creating a comprehensive system response model with nonlinear corrections that significantly boosts calibration efficiency multiple times over traditional methods.
AI-generated from the title and abstract; the full text is not read.
Key points
- Developed a comprehensive system response model for infrared radiation calibration that includes nonlinear corrections for optical attenuator and integration time.
- The unified framework enables full calibration method coverage, from collimator-blackbody to inner-outer calibration.
- The proposed method significantly increases calibration efficiency compared to traditional approaches.
- Unlike some fast methods, this approach does not require strict linearity in attenuation and integration time, broadening its applicability.
AI-generated from the title and abstract; the full text is not read.
Abstract
Abstract To overcome the limitation of long calibration time of traditional infrared radiation calibration methods, the paper presents the efficient calibration method for wide dynamic range infrared radiation measurement systems. First, by analyzing the energy transfer mechanism in systems incorporating variable optical attenuator and adjustable integration time settings, we develop the comprehensive system response model that accounts for the effects of both optical attenuator and integration time, incorporating nonlinear corrections in both dimensions. The model is designed to be universally applicable and can be seamlessly integrated with the inner-outer calibration concept, enabling full calibration method coverage—from collimator-blackbody and close-range extended source to inner-outer calibration—within a unified efficient framework. Consequently, the efficient calibration algorithm is derived based on the model, utilizing nonlinear optimization for parameter estimation. Experiments demonstrate that the proposed method boosts calibration efficiency multiple times relative to traditional approaches Furthermore, compared to Yang's fast calibration method, the approach does not require strict linearity in the attenuation and integration time dimensions, making it applicable to a broader range of infrared radiometric systems.
The authors' abstract, as published at the source. Scientific Reports, 2026 · DOI ↗
Continue with a free account
Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Aerospace Engineering
Aerospace EngineeringEngineering