PofoliaDaily literature tracker

Safety Science· 2026Q1

Analysis of counterflow-induced congestion propagation in a high-rise office building staircase: evidence from a full-building phased evacuation drill

Taehyeong Kim, SeongKyung Park, Masayuki Mizuno

Short summary

A single ascending pedestrian in a high-rise staircase triggered a congestion stop wave that propagated across 12 floors (3F-14F) and lasted up to 38 seconds at higher floors, with congestion density increasing from 1.36 p/m² to 2.18 p/m².

AI-generated from the title and abstract; the full text is not read.

Key points

  • A single ascending pedestrian in a high-rise staircase initiated a congestion stop wave affecting 14 floors.
  • The stop wave spanned 12 floors (3F-14F) for at least 3 seconds.
  • Congestion duration increased with floor height, from 10s at Floor 3 to 38s at Floor 13.
  • Peak pedestrian density increased from a normal-flow mean of 1.36 p/m² to a congested mean of 2.18 p/m² across affected floors.
  • The congestion front propagated at 0.861 m/s over Floors 3-14.

AI-generated from the title and abstract; the full text is not read.

Abstract

In high-rise fire emergencies, ascending firefighters must enter the staircase while occupants are still descending—a structurally unavoidable form of bidirectional flow. Counterflow is recognized as a contributor to staircase congestion, but its building-wide propagation has not been quantified from field data. This observational field study analyzes video counts from a full-building evacuation drill at a 22-story office building (≈2,400 participants); the drill was conducted as a phased evacuation, which serves as the observational context. The analysis focuses on a counterflow event during the normal flow period—after phase-related merging had concluded—isolating counterflow effects from merging. A single pedestrian ascending from Floor 1 to Floor 2 was followed by flow disruption across 14 floors (M2–14F); the stop wave satisfying the ≥ 3-s criterion spanned 12 floors (3F–14F). Congestion duration increased with floor height, from 10 s at Floor 3 to a maximum of 38 s at Floor 13, whereas peak density showed no floor-level trend but was uniformly elevated across affected floors, from a normal-flow mean of 1.36 p/m 2 to a congested mean of 2.18 p/m 2 . The apparent congestion front speed over Floors 3–14 was 0.861 m/s, with onset time increasing almost linearly with path distance, indicating a single coherent front; the resolution front advanced at 0.734 m/s, about 15 % more slowly. These findings provide field-based evidence of the floor-by-floor amplification of congestion duration and motivate—as a safety hypothesis requiring further validation—counterflow-aware evacuation planning where firefighter ascent may coincide with occupant descent.

The authors' abstract, as published at the source. Safety Science, 2026 · DOI ↗

TakeawaysPremium Ask the paperFree account

Continue with a free account

Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Safety Research

Safety ResearchSocial Sciences