PofoliaDaily literature tracker

ACS Sensors· 2026Q1

From Sensor Design to Force Maps: A Systematic Evaluation of Förster Resonance Energy Transfer-Based Tension Probes

Samet Aytekin, Sarah Vorsselmans, Giel Vankevelaer, Bert Poedts et al.

Short summary

A systematic evaluation of vinculin tension sensors revealed that the Clover-mScarlet-I fluorophore pair offers a broader dynamic range, and binary-response sensors FL and CC-S2 exhibit the largest force-dependent FRET changes for measuring piconewton-scale forces in living cells.

AI-generated from the title and abstract; the full text is not read.

Key points

  • The Clover-mScarlet-I fluorophore pair offers a broader dynamic range for FRET-based tension probes.
  • Binary-response sensors FL and CC-S2 showed the largest force-dependent FRET changes.
  • Fluorophore orientation significantly influences FRET readout in a module-dependent manner.
  • Unloaded reference constructs were used to establish a no-force baseline and validate force-dependent readings.

AI-generated from the title and abstract; the full text is not read.

Abstract

Mechanical forces transmitted through focal adhesions regulate cell behavior and disease progression, yet remain difficult to quantify at the molecular level. Genetically encoded FRET-based tension probes enable measurements of piconewton-scale forces across specific proteins in living cells, but their quantitative interpretation is highly sensitive to probe design and measurement modality. Here, we systematically compared vinculin tension sensors under identical experimental conditions, evaluating unloaded reference constructs, fluorophore pairs, mechanical sensor modules, and circularly permuted variants. Unloaded controls established a common no-force baseline and validated force-dependent readout. Among the fluorophore pairs tested, the green-red combination Clover-mScarlet-I yielded a higher unloaded FRET efficiency and hence a broader measurable dynamic range. Comparison of six mechanical sensor modules showed that the binary-response sensors FL and CC-S2 produced the largest force-dependent FRET changes and the steepest proximal-to-distal tension gradient. Circular permutation experiments revealed that fluorophore orientation has a strong, module-dependent influence on the measured FRET readout. Together, these results establish a comparative framework for interpreting FLIM-based vinculin tension measurements and provide practical design principles for selecting and engineering molecular tension probes.

The authors' abstract, as published at the source. ACS Sensors, 2026 · DOI ↗

TakeawaysPremium Ask the paperFree account

Continue with a free account

Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

BiophysicsBiochemistry, Genetics and Molecular Biology