PofoliaDaily literature tracker

World Journal of Surgical Oncology· 2026Q1

CEUS-guided hookwire localization combined with methylene blue staining for sentinel lymph node detection: a single-center clinical study

Yao Wang

Short summary

Combining contrast-enhanced ultrasound (CEUS)-guided hookwire localization with methylene blue staining achieved a 96.77% sentinel lymph node (SLN) detection rate in 62 patients, with both methods showing complementary identification patterns.

AI-generated from the title and abstract; the full text is not read.

Key points

  • The combined CEUS-guided hookwire localization and methylene blue staining method detected sentinel lymph nodes (SLNs) in 96.77% of 62 patients.
  • CEUS identified SLNs in 58 patients (93.54%), while methylene blue identified them in 59 patients (95.16%), indicating complementary roles.
  • SLN metastasis was found in 6 patients (9.68%), with all cases detected by at least one of the two modalities.
  • A trend suggested higher CEUS imaging grades were associated with increased SLN positivity.

AI-generated from the title and abstract; the full text is not read.

Abstract

Accurate identification of sentinel lymph nodes (SLNs) is essential for tumor staging and surgical decision-making. Although dye-guided SLN biopsy is widely used in clinical practice, relying on a single detection modality may lead to imprecise localization or missed detection of SLNs. Contrast-enhanced ultrasound (CEUS) has recently emerged as a promising imaging technique for visualizing lymphatic drainage and identifying SLNs. This study aimed to evaluate the complementary detection performance of CEUS-guided hookwire localization combined with methylene blue staining for SLN identification and to explore the potential predictive value of CEUS imaging grade for SLN metastasis. A total of 62 patients who underwent SLN biopsy were included in this single-arm clinical study. All patients underwent preoperative CEUS-guided hookwire localization followed by intraoperative methylene blue staining for SLN identification. The detection patterns of SLNs by CEUS and methylene blue were recorded and compared. In addition, CEUS imaging classified lymph nodes into three grades (I, II, and III), and the association between CEUS grade and pathological SLN metastasis was analyzed. SLNs were successfully identified in 60 of 62 patients, yielding an overall detection rate of 96.77%. A total of 222 sentinel lymph nodes were excised from 62 patients, with a mean of 3.63 nodes per patient.CEUS-guided hookwire localization and methylene blue staining demonstrated partial overlap in SLN identification. On a patient basis, 58 patients (93.54%) were identified by CEUS-guided hookwire localization, whereas 59 patients (95.16%) were identified by methylene blue staining, indicating complementary performance between the two techniques. Pathological examination revealed SLN metastasis in 6 patients (9.68%). All metastatic cases were detected by at least one of the two modalities. A trend toward increasing SLN positivity was observed across CEUS imaging grades (Grade I: 5.88%, Grade II: 11.54%, Grade III: 16.67% ). CEUS-guided hookwire localization combined with methylene blue staining demonstrates complementary value in SLN detection. CEUS imaging features show a trend toward higher SLN positivity; however, their predictive value for nodal metastasis remains exploratory and should be interpreted with caution.

The authors' abstract, as published at the source. World Journal of Surgical Oncology, 2026 · DOI ↗

TakeawaysPremium Ask the paperFree account

Continue with a free account

Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Pathology and Forensic Medicine

Pathology and Forensic MedicineMedicine