CVIR Endovascular· 2026Q2
Portable endovascular disposable robotic assistant (PEDRA) for image-guided peripheral endovascular interventions: technical feasibility, safety, and future implications
- 1citations
- Q2SCImago
- 2026year
Short summary
A portable, disposable robotic system (LIBERTY®) achieved 100% technical success in 20 diverse endovascular procedures, including first-time robotic use for prostate artery embolization, uterine fibroid embolization, and radial access interventions.
AI-generated from the title and abstract; the full text is not read.
Key points
- The portable, disposable LIBERTY® robotic system achieved 100% technical success in 20 endovascular procedures.
- Complete robotic target-vessel selection was achieved in 75% of cases, improving to 100% with updated hardware.
- The system was used for the first documented robotic-assisted prostate artery embolization, uterine fibroid embolization, and radial access interventions.
- No serious adverse events related to the robotic device were reported.
AI-generated from the title and abstract; the full text is not read.
Abstract
BACKGROUND: Traditional fixed-console endovascular robots face barriers due to high capital costs and infrastructure requirements. This study evaluates the technical feasibility and safety of the LIBERTY® Endovascular Robotic System-a portable, disposable platform-across diverse Interventional Radiology procedures and vascular access sites. MATERIALS AND METHODS: A single-center retrospective review was conducted on 20 consecutive outpatient procedures performed by five operators. Cases included prostate artery embolization, uterine fibroid embolization, renal/gonadal venography, geniculate artery embolization, Y90 mapping, and Y90 radioembolization. Vascular access points included left radial and femoral approaches. RESULTS: Procedural technical success was achieved in 100% (20/20) of cases. 100% of vessels attempted with robotic assistance were successfully selected (31/31). Complete robotic target-vessel selection-performing all procedural aspects of vessel selection robotically-was 75% (15/20). Partial robotic target-vessel selection-conversion to manual prior to completion of all vessel selections with robotic assistance-was 25% (5/20). All 5 cases of partial robotic target-vessel selection were due to hardware malfunction, rather than an inability to select target vessels with robotic assistance. Subgroup analysis of the last 10 cases after switching to utilizing updated units demonstrated 100% complete robotic target-vessel selection (10/10). No device-related serious adverse events or complications occurred. CONCLUSION: The portable and disposable robotic platform was successfully integrated into a diverse Interventional Radiology practice, demonstrating the first documented prostate artery embolization, uterine fibroid embolization, renal/gonadal venography, geniculate artery embolization, and Y90 procedures by portable and disposable robotic-assistance, as well as the first robotic-assisted endovascular procedures via radial access. Its design may lower economic and institutional barriers, potentially expanding robotic-assisted interventions to rural or non-academic settings. The portable robotic assistant is safe and feasible for complex endovascular interventions. Further prospective studies are needed to quantify ergonomic benefits and radiation reduction.
The authors' abstract, as published at the source. CVIR Endovascular, 2026 · DOI ↗
Continue with a free account
Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Pulmonary and Respiratory Medicine
Pulmonary and Respiratory MedicineMedicine