Experimental Physiology· 2026Q2
Evaluating the effects of changes in minute ventilation and the partial pressure of end‐tidal carbon dioxide on the diaphragm electromyogram during voluntary hyperpnoea
- 0citations
- Q2SCImago
- 2026year
Short summary
Diaphragm electromyogram (EMG DIA) reflects the mechanical ventilatory output of inspiratory neural drive (IND) during voluntary hyperpnea, rather than changes in the drive to breathe due to variations in end-tidal carbon dioxide (PETCO2). EMG DIA increased significantly with minute ventilation (VE) but was unaffected by changes in PETCO2.
AI-generated from the title and abstract; the full text is not read.
Key points
- Diaphragm electromyogram (EMG DIA) increased significantly with minute ventilation (VE) (P < 0.001).
- EMG DIA was not significantly affected by changes in end-tidal carbon dioxide (PETCO2) (P = 0.320).
- EMG DIA was significantly associated with VE, work of breathing, and diaphragm pressure-time product (R² = 0.762–0.824; all P < 0.001).
- Perception of dyspnea intensity increased significantly with both VE (P < 0.001) and PETCO2 (P < 0.001).
AI-generated from the title and abstract; the full text is not read.
Abstract
The diaphragm electromyogram (EMG DIA ) is commonly used as a proxy for inspiratory neural drive (IND) based on correlative evidence; however, robust experimental evidence supporting its use is lacking. To determine the effects of independent changes in minute ventilation () and the partial pressure of end‐tidal carbon dioxide () on EMG DIA . n = 10 healthy adults (20–40 years; n = 5 males, n = 5 females) completed spirometry, a 10‐min rest period and a series of hyperpnoea trials at three standardized levels of by having participants breathe according to tidal volume ( V T ) and breathing frequency ( F B ) targets. Within each level of , was set to −5, +0 or +5 mmHg relative to resting using dynamic end‐tidal forcing. Trials were performed in a quasi‐randomized, single‐blind manner. EMG DIA was assessed using an intraoesophageal catheter, standard ventilatory and gas exchange variables were collected, and the perception of dyspnoea intensity was assessed using the Borg category‐ratio 0–10 scale. EMG DIA increased significantly with ( P < 0.001) but was unaffected by changes in ( P = 0.320). Moreover, EMG DIA was significantly associated with , the work of breathing, and the pressure–time product of the diaphragm ( R 2 = 0.762–0.824; all P < 0.001), but not ( R 2 = 0.529; P = 0.947). Dyspnoea perception increased significantly with ( P < 0.001) and ( P < 0.001). During voluntary hyperpnoea involving manipulations of across a physiological range observed with exercise (i.e., 5 mmHg below and above resting ), EMG DIA reflects the mechanical ventilatory output of IND rather than changes in the drive to breathe due to variations in .
The authors' abstract, as published at the source. Experimental Physiology, 2026 · DOI ↗
Continue with a free account
Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Endocrine and Autonomic Systems
Endocrine and Autonomic SystemsNeuroscience