Neurophotonics· 2026Q1
Implications of temporal sampling in voltage imaging microscopy
- 1citations
- Q1SCImago
- 2026year
Short summary
Scanning microscopes excel at detecting sparse voltage spikes in low signal-to-noise conditions, while wide-field microscopes are superior when temporal undersampling occurs and most spikes need detection. Both perform similarly as sampling rates increase.
AI-generated from the title and abstract; the full text is not read.
Key points
- Scanning microscopes outperform wide-field microscopes in low signal-to-noise conditions for detecting sparse spikes.
- Wide-field microscopes are superior when temporal undersampling occurs and a large fraction of spikes needs detection.
- Performance of both modalities converges as sampling rates increase and approach the voltage indicator's decay rate.
- The study advises against using scanning voltage imaging microscopes at frame rates below 500 Hz.
AI-generated from the title and abstract; the full text is not read.
Abstract
Significance: . Various imaging approaches have been developed, including point-scanning, line-scanning, and wide-field microscopes; however, the effects of their different temporal sampling methods on signal fidelity have not yet been fully investigated. Aim: We aim to provide an analysis of the inherent advantages and disadvantages of temporal sampling in scanning and wide-field microscopes and their effect on the fidelity of voltage spike detection. Approach: We develop a mathematical framework based on a mixture of analytical modeling and computer simulations with Monte-Carlo approaches. Results: Scanning microscopes outperform wide-field microscopes in low signal-to-noise conditions and when only a small subset of spikes needs to be detected. Wide-field microscopes outperform scanning microscopes when the measurement is temporally undersampled and a large fraction of the spikes needs to be detected. Both modalities converge in performance as sampling increases and the frame rate reaches the decay rate of the voltage indicator. Conclusions: Our work provides guidance for the selection of optimal temporal sampling parameters for voltage imaging. Most importantly, it advises against using scanning voltage imaging microscopes at frame rates below 500 Hz.
The authors' abstract, as published at the source. Neurophotonics, 2026 · DOI ↗
Continue with a free account
Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
BiophysicsBiochemistry, Genetics and Molecular Biology