Journal of Analytical Science & Technology· 2026Q2
MALDI-TOF MS–based immunoassay using switching peptide for sensitive detection of intact foodborne bacteria
- 0citations
- Q2SCImago
- 2026year
Short summary
A novel homogeneous immunoassay using MALDI-TOF MS and switching peptides enables sensitive, quantitative detection of five intact foodborne bacteria (E. coli O157:H7, S. typhimurium, L. monocytogenes, S. aureus, B. cereus) without washing steps.
AI-generated from the title and abstract; the full text is not read.
Key points
- Developed a homogeneous immunoassay for five foodborne bacteria (E. coli O157:H7, S. typhimurium, L. monocytogenes, S. aureus, B. cereus) using MALDI-TOF MS.
- Quantification is achieved by detecting switching peptides released upon antigen-antibody binding, serving as mass tags.
- The assay operates in a homogeneous solution without washing steps.
- Demonstrated good linearity (R² > 0.983) over 0.01–10.00 pmol/µL and improved sensitivity compared to fluorescence and HPLC methods.
AI-generated from the title and abstract; the full text is not read.
Abstract
Abstract A matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS)–based immunoassay was developed for quantitative detection of five foodborne bacterial species: Escherichia coli O157:H7, Salmonella typhimurium , Listeria monocytogenes , Staphylococcus aureus , and Bacillus cereus . The assay was conducted in a homogeneous solution without washing steps and enabled quantification through detection of switching peptides (antibody-binding peptides released upon antigen binding) released upon antigen–antibody binding, which served as mass tags for MALDI-TOF MS readout. Target-specific antibodies were isolated from commercially available unimmunized pig serum using a stepwise filtration approach involving target and filter bacteria, yielding 130.4 ± 20.0 µg and 95.2 ± 26.6 µg for the first and second isolated antibodies from 1 mL of pig serum ( n = 5), respectively. Quantitative analysis of the switching peptides using an internal standard (P14R) exhibited good linearity over the concentration range of 0.01–10.00 pmol/µL, with relative standard deviations of 1.4%–11.3% and coefficients of determination exceeding 0.983. Compared with fluorescence- and high-performance liquid chromatography–based methods, MALDI-TOF MS achieved a lower limit of detection, demonstrating improved sensitivity for detecting low-abundance bacterial targets. The developed immunoassay enabled quantitative detection of the five bacterial species at lower bacterial cell numbers per test than fluorescence-based assays.
The authors' abstract, as published at the source. Journal of Analytical Science & Technology, 2026 · DOI ↗
Continue with a free account
Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Clinical Biochemistry
Clinical BiochemistryBiochemistry, Genetics and Molecular Biology