Journal of Magnetic Resonance Imaging· 2026Q1
Artifact Correction of Clinical Diffusion Weighted Imaging in Acute Ischemic Stroke
- 1citations
- Q1SCImago
- 2026year
Short summary
Structural imaging-based artifact correction improved geometric agreement and diagnostic accuracy of DWI in acute ischemic stroke patients, increasing specificity and positive predictive value for infarct detection.
AI-generated from the title and abstract; the full text is not read.
Key points
- Structural imaging-based artifact correction improved mutual information between DWI and FLAIR/T1-weighted images in acute stroke patients.
- ADC-defined infarct volumes showed strong correlation (R²=0.998) with DWI-defined infarct volumes before and after correction, with a bias of -0.51 mL.
- DWI hyperintensities after correction showed improved specificity (0.998) and positive predictive value (0.53) for ADC-defined infarcts compared to pre-correction values (0.997 and 0.39, respectively).
- The correction method reduces false positive hyperintensities, thereby improving the diagnostic utility of DWI in acute ischemic stroke.
AI-generated from the title and abstract; the full text is not read.
Abstract
ABSTRACT Background Susceptibility‐induced geometric distortions and non‐physiologic hyperintensities confound acute ischemic stroke diagnosis on diffusion weighted imaging (DWI). Reverse phase‐encoded imaging needed for artifact correction is rarely acquired acutely. Structural imaging‐based correction is validated in healthy subjects, but its efficacy in acute stroke remains unclear. Purpose To investigate whether structural imaging‐based artifact correction reduces DWI distortions and non‐physiologic hyperintensities in clinical acute stroke imaging. Study Type Retrospective. Population 214 patients with acute ischemic stroke and clinical MRI from two centers. Field Strength/Sequences 1.5 T/3 T; single‐shot echo planar DWI; 3D MP‐RAGE and 2D spin echo, gradient echo, turbo spin echo, and turbo inversion recovery T1‐weighted sequences; 2D turbo spin echo and BLADE FLAIR sequences. Assessment DWI distortions were corrected using the Synb0‐DisCo and TOPUP algorithms with b0 and T1‐weighted images. Mutual information evaluated geometric agreement against FLAIR and T1‐weighted images before and after correction. The diagnostic value of hyperintense DWI lesions for apparent diffusion coefficient (ADC)‐defined reference infarct was assessed. Statistical Tests Wilcoxon sign rank or rank sum tests of mutual information, sensitivity, specificity, and positive and negative predictive value; Bland–Altman plots; and linear regression with coefficients of determination ( R 2 ) in linear and log space. Bonferroni‐adjusted p < 0.05 was significant. Results After correction, DWI demonstrated significantly increased mutual information against FLAIR images [0.31 (IQR, 0.25–0.38) versus 0.30 (0.24–0.35)] and T1‐weighted images [0.32 (IQR, 0.29–0.36) versus 0.29 (0.24–0.33)]. ADC‐defined infarct volumes before and after correction correlated strongly ( R 2 0.998, log 0.541) with a negative bias of 0.51 (95% CI, 0.18–0.85) mL. DWI hyperintensities before and after correction correlated strongly ( R 2 0.996, log 0.360) but demonstrated a negative bias of 2.47 (95% CI, 1.95–3.00) mL. After correction, DWI hyperintensities demonstrated significantly improved specificity [0.998 (IQR, 0.994–1.000) versus 0.997 (0.992–0.999)] and positive predictive value [0.53 (IQR, 0.31–0.77) versus 0.39 (0.16–0.63)] for ADC‐defined infarct. Data Conclusion Structural imaging‐based distortion correction of routinely acquired clinical DWI in acute ischemic stroke improves anatomic geometry and reduces false positive hyperintensities. Evidence Level 3. Stage of Technical Efficacy 3.
The authors' abstract, as published at the source. Journal of Magnetic Resonance Imaging, 2026 · DOI ↗
Continue with a free account
Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Radiology, Nuclear Medicine and Imaging
Radiology, Nuclear Medicine and ImagingMedicine