Nonlinear static pushover and time history analyses reveal that plan symmetry and vertical continuity are key criteria for selecting retrofit schemes for Bagan's monumental heritage buildings, with analytical estimates provided for spire shear failure.
AI-generated from the title and abstract; the full text is not read.
Key points
- Nonlinear static pushover and time history analyses were performed on 3D finite element macro-models of four Bagan heritage buildings.
- Simulations were validated against seismic damage observed in the 1975 and 2016 earthquakes.
- Seismic rocking analysis was conducted on nonstructural elements like spires, with estimates for acceleration levels causing shear failure.
- Plan symmetry and vertical continuity were identified as key criteria for selecting seismic retrofit schemes.
AI-generated from the title and abstract; the full text is not read.
Abstract
This paper presents the outcomes of nonlinear static pushover and time history analyses, using both recorded and simulated ground motion signals, on 3D finite element macro-models of four buildings representative of Bagan’s monumental heritage: Myin-pya-gu (1493), Zan-thi (east) (558), Tha-mu-ti-hpaya (844), and Kya-zin-hpaya (1219). The simulations are validated against the observed seismic damage in the 1975 and 2016 earthquakes. The results of the nonlinear finite element method (NLFEM) analyses are complemented by seismic rocking analysis conducted on nonstructural elements, such as spires, through nonlinear kinematic analysis. Analytical estimates of acceleration levels capable of causing shear failure in spires are provided, focusing on elements with a slenderness ratio that makes them vulnerable to shearing rather than rocking (i.e. flexure-controlled) failure modes. A comparative assessment of seismic performance is presented for the four buildings, highlighting the influence of plan symmetry and vertical continuity. These attributes are proposed as key criteria for selecting appropriate retrofit schemes to protect Bagan’s monuments against future seismic events.
The authors' abstract, as published at the source. International Journal of Architectural Heritage, 2026 · DOI ↗
Continue with a free account
Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Civil and Structural Engineering
Civil and Structural EngineeringEngineering