Measurement Science and Technology· 2026Q2
Enhancement of the super-resolved optical photothermal infrared signal at lower temperatures
- 1citations
- Q2SCImago
- 2026year
Short summary
Cooling samples to subzero temperatures significantly enhances the optical photothermal infrared (O-PTIR) signal by up to three times, improving analytical sensitivity and reducing the limit of detection for protein films from 400 nm to 300 nm.
AI-generated from the title and abstract; the full text is not read.
Key points
- O-PTIR microscopy can now be performed at subzero temperatures down to -100 °C.
- Cooling samples enhances the O-PTIR signal by up to three times, with optimal enhancement between -20 °C and -40 °C.
- The limit of detection for thin protein films was reduced from approximately 400 nm to 300 nm.
- The study investigates the physical mechanisms, including thermal conductivity and heat dissipation, behind the signal amplification.
AI-generated from the title and abstract; the full text is not read.
Abstract
Optical photothermal infrared (O-PTIR) microspectroscopy is an emerging label-free technique that achieves infrared super-resolution and has found widespread applications, primarily in soft materials. While the photothermal effect underlying O-PTIR has been extensively studied at room temperature, there was an open question whether the signal itself would benefit from a lower temperature, as the photoinduced heating could be more localized, thus increasing the signal. In this work, we integrated a temperature-controlled stage into an O-PTIR microscope, enabling the first spectroscopic measurements and imaging of samples at subzero temperatures down to -100 °C. Using tristearin, biological tissue, and polymer samples, we demonstrated that cooling significantly enhances the O-PTIR signal up to three times, with a maximum observed in the -20 to -40 °C range. This enhancement leads to an improved analytical sensitivity, reducing the limit of detection for a thin protein film from ca. 400 nm to ca. 300 nm. We further discuss the underlying physical mechanism, including thermal conductivity and heat dissipation effects, that contribute to the observed temperature-dependent signal amplification. Overall, this study establishes temperature-controlled O-PTIR as a powerful new approach for high-sensitivity, high-resolution infrared analysis, thereby expanding its applicability to a broader range of materials and experimental conditions.
The authors' abstract, as published at the source. Measurement Science and Technology, 2026 · DOI ↗
Continue with a free account
Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
BiophysicsBiochemistry, Genetics and Molecular Biology