PofoliaShared via Pofolia

Critical Care· 2026Q1

Toward targeted assessment of inspiratory muscle weakness before extubation: a Pooled individual patient data analysis from multiple observational cohorts in critically ill ventilated patients

Clément Médrinal, Margaux Machefert, Claire Dubois, Guillaume Fossat et al.

Short summary

Maximal inspiratory pressure (MIP) ≤ 30 cmH₂O is associated with extubation failure (adjusted OR 3.52) in critically ill patients ventilated for >5 days, but not in the general ventilated population.

AI-generated from the title and abstract; the full text is not read.

Key points

  • Maximal inspiratory pressure (MIP) ≤ 30 cmH₂O was associated with extubation failure (adjusted OR 3.52, p=0.009) in patients ventilated for >5 days.
  • In the overall population of 494 patients, MIP ≤ 30 cmH₂O showed only a borderline association with extubation failure (OR 1.94, p=0.06).
  • Other neuromuscular assessments (MEP, PCF, MRC score) did not show significant adjusted associations with extubation failure.
  • Extubation failure occurred in 33% of patients with MIP ≤ 30 cmH₂O versus 14% with MIP > 30 cmH₂O after prolonged ventilation (>5 days).

AI-generated from the title and abstract; the full text is not read.

Abstract

Bedside neuromuscular tests are commonly proposed to assess readiness for extubation in critically ill patients. However, when used in unselected populations, their ability to predict clinically relevant outcomes such as extubation failure has been inconsistent. A more targeted use of these tests, restricted to patients in whom neuromuscular weakness is more likely to contribute to weaning failure, may improve their clinical relevance. We conducted a pooled individual patient data analysis of multiple observational cohorts including adult ICU patients receiving invasive mechanical ventilation. The primary outcome was extubation failure, defined as reintubation or death within 48 h after extubation. Available neuromuscular assessments included maximal inspiratory pressure (MIP), maximal expiratory pressure (MEP), peak cough flow (PCF), and Medical Research Council (MRC) sum score. Prespecified thresholds were MIP ≤ 30 cmH₂O, MEP ≤ 50 cmH₂O, PCF ≤ 60 L/min, and MRC < 48/60. Associations with extubation failure were assessed in the overall population and according to prior mechanical ventilation duration. Among 494 included patients, 458 had an available extubation outcome and 72 (16%) experienced extubation failure. MIP was available in 230 patients, MEP in 124, PCF in 156, and MRC score in 252. In the overall population, MIP ≤ 30 cmH₂O showed only a borderline association with extubation failure (24% vs. 14%; OR 1.94, 95% CI 0.98 to 3.84; p = 0.06). In patients ventilated for more than 5 days, extubation failure occurred in 33% with MIP ≤ 30 cmH₂O versus 14% with MIP > 30 cmH₂O. After adjustment, MIP ≤ 30 cmH₂O remained associated with extubation failure (adjusted OR 3.52, 95% CI 1.37 to 9.03; p = 0.009). No significant adjusted association was observed for MEP, PCF, or MRC. Neuromuscular tests may have limited prognostic value when applied broadly before extubation. Low MIP appears more informative after prolonged mechanical ventilation, supporting a targeted rather than systematic use of respiratory neuromuscular assessment before extubation.

The authors' abstract, as published at the source. Critical Care, 2026 · DOI ↗

TakeawaysPremium
Ask the paperFree account

Continue with a free account

Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Critical Care and Intensive Care Medicine

Critical Care and Intensive Care MedicineMedicine