PofoliaShared via Pofolia

Computer Methods and Programs in Biomedicine· 2026Q1

SDFStent: Real-time interactive virtual stenting via SDF deformation fields

Bohan Li, Nicholas C. Dorn, András Lassó, Matthew A. Jolley et al.

Short summary

SDFStent, a novel signed distance function (SDF) based mesh deformation method, enables real-time virtual stenting, achieving a mean stented diameter of 5.92 ± 0.08 mm in 1.5 seconds, over 100x faster than existing comparators.

AI-generated from the title and abstract; the full text is not read.

Key points

  • SDFStent achieves virtual stenting in 1.5 seconds, producing a mean diameter of 5.92 ± 0.08 mm, over 100x faster than comparators.
  • The method ensures watertight and self-intersection-free output meshes.
  • CFD-simulated post-operative pressure drops agreed with clinical measurements within a mean error of 2 mmHg.
  • The implementation is open-source and integrated into 3D Slicer.

AI-generated from the title and abstract; the full text is not read.

Abstract

BACKGROUND AND OBJECTIVE: Stenting is among the most common transcatheter interventions for congenital heart disease (CHD). Patient-specific computational fluid dynamics (CFD) simulations can predict hemodynamic outcomes of intervention scenarios but require post-operative vascular geometries that reflect stent-induced shape changes, which existing tools either model inadequately or require extensive time or manual effort to generate. We present SDFStent, a signed distance function (SDF) based mesh deformation method for virtual stenting that operates in real time, maintains mesh integrity, and preserves junction geometry. METHODS: The stent is modeled as a pipe surface composed of piecewise-capsule SDFs joined by a smooth-minimum operator. Mesh vertices near the expanding SDF surface are displaced along the SDF gradient with a compactly supported fall-off function and an alpha blending mask. SDFStent was benchmarked against three existing approaches and validated on a proof-of-concept cohort of three tetralogy of Fallot (ToF) and three coarctation of the aorta (CoA) patients using rigid-wall steady-state CFD simulations against clinical catheterization measurements. RESULTS: Against a prescribed diameter of 6.0 mm, the method produced a mean stented diameter of 5.92 ± 0.08 mm in 1.5 s, over 100× faster than the best stenting-specific comparator. All output meshes were watertight and self-intersection-free. CFD-simulated post-operative pressure drops agreed with clinical measurements within 4 mmHg (mean error 2 mmHg). CONCLUSIONS: SDFStent produces simulation-ready post-stent models that match prescribed stent dimensions at interactive speeds, from pre-operative anatomy and catheterization data alone. The implementation is open-source and available in 3D Slicer. Its scriptable architecture enables automated generation of large synthetic cohorts for data-driven surrogate modeling.

The authors' abstract, as published at the source. Computer Methods and Programs in Biomedicine, 2026 · DOI ↗

TakeawaysPremium
Ask the paperFree account

Continue with a free account

Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Computer Graphics and Computer-Aided Design

Computer Graphics and Computer-Aided DesignComputer Science