Surgical Endoscopy· 2026Q1· Review

Tissue effects of advanced energy devices: a systematic review and descriptive analysis of vascular sealing and lateral thermal damage in human tissue

Daniel R. Marshall, N. Kahar, C. Challand, L. Wyld

Short summary

A systematic review of 28 human studies found that most advanced energy devices achieve vessel seals exceeding physiological burst pressures, though seal failures are unpredictable and lateral thermal spread varies widely (0–7.64 mm).

AI-generated from the title and abstract; the full text is not read.

Key points

  • Most vessel seals created by bipolar and ultrasonic devices in human tissue exceed physiological burst pressures.
  • Seal failures with these devices occur unpredictably.
  • Lateral thermal spread varies significantly (0–7.64 mm) across studies.
  • Variability in lateral thermal spread depends on the device, tissue, testing methodology, and definitions used.

AI-generated from the title and abstract; the full text is not read.

Abstract

Abstract Introduction Advanced energy devices such as bipolar and ultrasonic devices are used ubiquitously in all aspects of surgery. Despite studies demonstrating differences between animal and human tissues, existing human studies have only been conducted in terms of operative outcomes such as blood loss, with a paucity of data on vessel sealing and lateral thermal spread. This study aims to consolidate all existing literature on these characteristics for each device in human tissues to inform clinician decision making. Methods A systematic review of the literature was carried out using PRISMA guidelines. Papers which discussed vessel sealing or lateral thermal spread with any methodology were included. Exclusion criteria included animal studies, conference abstracts or papers where full text English language papers were not available. Risk of bias was assessed using ROB2, ROBINS-I v2, CASP case–control and JBI case series checklists as appropriate for the study design. A descriptive analysis was undertaken. Results and discussion Across the twenty-eight included studies, most vessel seals with bipolar and ultrasonic devices exceeded physiological burst pressures. Seal failures occurred unpredictably. Lateral thermal spread varied widely (0–7.64 mm) depending on the device and tissue examined as well as the testing methodology and definitions of lateral thermal spread. Due to substantial variation in study methods, direct statistical comparisons were not possible and a reliable device-to-device comparison cannot currently be made from the available literature. This highlights the need for standardized testing methodology. PROSPERO registration and full protocol availability: CRD420251239034

The authors' abstract, as published at the source. Surgical Endoscopy, 2026 · DOI ↗